Alcatel-Lucent 7250 SAS manual Physical interfaces

Models: 7250 SAS

1 6
Download 6 pages 63.85 Kb
Page 4
Image 4
Physical interfaces

Pseudo-wire status-notification message according to RFC 4447

Local loopback for TDM port

Local loopback for CES service

Bit error-rate test on the local TDM port

Physical interfaces

10/100Base-T:

¬Connectors: RJ-45

¬Transmission: Full/half duplex

¬Range: 100 m (328.08 ft)

¬Ports: Auto-sensing

100Base-FX: SFP-based, LC connector

1000Base-X: SFP-based, LC connector

4-port DS1/E1 module: E1/T1 to RJ-48c connector

4 dry contact inputs through a DB-9 connector

Dimensions

Height: 44 mm (1.73 in.)

Width: 440 mm (17.32 in.)

Depth: 419 mm (16.5 in.)

Weight

Chassis without power supply unit (PSU): 3.7 kg (8.2 lb)

Single AC power supply: 0.6 kg (1.3 lb)

Single DC power supply: 0.6 kg (1.3 lb)

Power supply

Redundant, hot-swappable

AC version: 100 V to 240 V, 50/60 Hz

DC (-48 V) version: -36 V to -75 V

Power consumption: 90 W maximum

Certification

Safety: EN 60950-1 (2001), AS/NZS 60950.1 (2003)

EMC

¬Emissions EN 55022 - 1998/A1 - 2000/A2 - 2003

¬ICES-003 Issue 4 Class A

¬FCC 47 CFR Part 15 Class A

¬VCCI Class A

¬AS/NZS CISPR 22 - 2002 Class A

¬EN 61000-3-2 - 2000

¬EN 61000-3-3 - 1995/A1 - 2001

Immunity

¬EN 55024 - 1998/A1 - 2001/A2 - 2003

Emissions and Immunity

¬EN 300 386 v1.3.2

Network Equipment Building System (NEBS) Level 3 compliant

CES Module and High Performance CES Module

¬AS/ACIF S016 - 2001

¬FCC Part 68; TIA-968-A/A1, A2, A3; Industry Canada, IC-CS03

¬TBR 12 - 1993/A1 - 1996

Environment

Operating temperature: 0ºC to 45ºC (32º F to 113ºF)

Short-term extended temperature: -20ºC to +60 C (-4ºF to +140ºF)

Humidity: Up to 95%, non- condensing

Network management

The 7250 SAS is supported by the 5620 SAM, including:

¬5620 SAM-E

¬5620 SAM-P

¬5620 SAM-A

Standard management support includes:

¬STD-15

¬SNMPv1

¬STD-16 SMIv1

¬STD-17 MIB-11

¬STD-50 EtherLike MIB

¬STD-58 SMIv2

¬STD-59 RMON

¬STD-62 SNMPv3

¬SNMPv2c

¬SNMPv1

¬RFC 2668 MAU

¬RFC 29250

¬Ping MIB

Command line interface (CLI)

¬Serial

¬Telnet

¬Secure Shell (SSH)

Interface: In-band/out-of-band

Local interface: RJ-45, TIA/ EIA-232

Software download: Trivial File Transfer Protocol (TFTP)

Remote Authentication Dial-In User Service (RADIUS)

Syslog

Standards compliance

IEEE standards

IEEE 802.1d Spanning Tree Algorithm

IEEE 802.1p Priority Queuing

IEEE 802.1q VLAN Tagging

IEEE 802.1w Rapid Spanning Tree

IEEE 802.1s Multiple Spanning Tree

IEEE 802.1ad Provider Edge Bridges

IEEE 802.1ag Connectivity Fault Management

IEEE 802.3ad Link Aggregation

IEEE 802.3 Ethernet CSMA/CD Access Method and Physical Layer Specifications

IEEE 802.3ah Ethernet First Mile

IEEE 802.3u Fast Ethernet

IEEE 802.3x Flow Control on Access

IEEE 802.3z Gigabit Ethernet

IETF specifications

General

RFC 768 User Datagram Protocol

RFC 783 TFTP

RFC 791 Internet Protocol

RFC 792 Internet Control Message Protocol

RFC 793 Transmission Control Protocol

RFC 826 Ethernet Address Resolution Protocol

RFC 854 Telnet Protocol Specification

RFC 1122 Requirements for Inter- net Hosts - Communication Layers

RFC 1518 Classless Inter-Domain Routing (CIDR) Architecture

RFC 1519 Classless Inter-Domain Routing (CIDR)

RFC 1812 Requirements for IPv4 Routers DiffServ

RFC 2474 Definition of the Differ- entiated Services Field (DS Field) in IPv4 and IPv6 Headers

RFC 2475 DiffServ Core and Edge Routing Functions

RFC 2597 DiffServe Assured Forwarding

RFC 3140 Per Hop Behavior Identification Codes

RFC 3246/2598 Expedited For- warding PHB

Table 1. 7250 SAS platform variant requirements for key features

Key Feature

7250 SAS* (3HE01188AA)

7250 SAS ES (3HE01189AA)

7250 SAS ESA (3HE03250AA)

 

 

Ethernet switching and bridging

CES

Enhanced GigE uplink (with H-QoS,

 

MPLS, FRR, RSVP-TE)

 

 

 

Dry contact inputs, loose-hop LSPs,

 

 

dynamic bypass LSPs, 5620 SAM support

 

 

 

for Server Assignment Answer (SAA),

 

 

 

pseudo-wire status message

 

 

 

 

 

 

 

* Note: A 7250 SAS standard-variant manufacturer-discontinuation notification was issued in October 2007.

Alcatel-Lucent 7250 SAS Data Sheet

4

Page 4
Image 4
Alcatel-Lucent 7250 SAS manual Physical interfaces