Alcatel-Lucent 7549 MGW manual Technical specifications, Protocol support, Voice CODECs, Power

Models: 7549 MGW

1 2
Download 2 pages 28.44 Kb
Page 2
Image 2
Technical specifications

Technical specifications

Protocol support

Wireless networks

TDM

ATM

IP

SGW

M3UA/SIGTRAN

MTP3 NB

MTP3 BB

Network attachment compliance

ITU-T G.703

ITU-T G.707

ITU-T G.813

ITU-T G.823

ITU-T G.825

ITU-T G.957

Voice CODECs

G.711

G.729ab

EFR

GSM HR

GSM FR

GSM EFR

GSM AMR HR

GSM AMR FR

AMR

AMR2

AMR2 WB

Physical specifications

Chassis dimensions

Height: 62.2 cm (24.5 in.)

Width: 45.2 cm (17.4 in.)

Depth: 47.3 cm (18.6 in.)

Rack dimensions

Height: 200 cm (78.7 in.)

Width: 60 cm (23.6 in.)

Depth: 80 cm (31.5 in.)

Power

Input voltage -40V DC to -60V DC

Input current 65 A, dual feeds

Power consumption: 3000 W

Operating temperature

5°C to 40°C (41°F to 104°F)

Regulatory compliance

Electromagnetic compatibility (EMC)

EN 300 386: Telecommunica­ tion Network Equipment, EMC requirements

EC 61000-4: Testing and measurement techniques

IEC 61000-4-2: Electrostatic discharge

IEC 61000-4-3: Radiated, radio frequency, electromagnetic field

IEC 61000-4-4: Electrical fast transient/burst

IEC 61000-4-5: Surge immunity

IEC 61000-4-6: Immunity to conducted disturbances, induced by radio-frequency fields

Telcordia GR-1089-CORE Iss 4, Sections 2, 3, 4, 5, 6, 10

Safety

UL 60950-1, 1st ed.: Safety of information technology equipment

CSA 22.2 60950-1-03 1st. ed.: Safety of information technology equipment

CB Scheme/IEC 60950-1 1st ed.: Safety of information technology equipment

Power and grounding requirements

Telcordia GR-1089-CORE, Section 9 Bonding and Grounding

Climatic and mechanical

ETS 300 019-2-1: Environmental conditions and environmental tests for telecommunications equipment – Part 21: Specifica- tion of environmental tests: storage

ETS 300 019-2-2: Environmental conditions and environmental tests for telecommunications equipment – Part 22: Specifica- tion of environmental tests: transportation

ETS 300 019-2-3: Environmental conditions and environmental tests for telecommunications equipment – Part 23: Specifica- tion of environmental tests: stationary use at weather- protected locations

Telcordia GR-63-CORE Iss 3, Sections 2, 4.1.1, 4.1.2, 4.1.3, 4.1.6

Fire resistance

Telcordia GR-63-CORE, Sections 4.2 and 5.2

Seismic

ETS 300 019-2-3/A1

Telcordia GR-63-CORE Iss 3, Section 4.4.1

Acoustics

ETS 300 753 Class 3.1 (1997): Acoustic noise emitted by tele- communications equipment

Telcordia GR-63-CORE Iss 3, Section 4.6

www.alcatel-lucent.comAlcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other trademarks are the property of their respective owners. The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility for inaccuracies contained herein. Copyright © 2008 Alcatel-Lucent. All rights reserved.

CAR9718081120 (12)

Page 2
Image 2
Alcatel-Lucent 7549 MGW manual Technical specifications, Protocol support, Voice CODECs, Physical specifications, Power