FILTER REPLACEMENT INSTRUCTIONS - 4000,5000,6000 & 8000 SERIES
AllerAir Industries Inc. Toll Free:
REPLACE THE
STEP 1 | STEP 2 | STEP 3 |
Make sure the unit is | Slowly remove the dirty filter | Insert the new filter by |
set to "off" and the | to avoid dispersing its contents. | pressing it gently against |
unit is unplugged. | Gently insert it into a plastic bag | the sides of the carbon |
Lay the unit on its side. | before discarding. | filter inside the unit |
REPLACE CARBON & HEPA FILTERS
These replacement filters will extend the life of your AllerAir unit. Please be sure to follow the instructions for changing the filters in your unit.
We recommend changing pre- filters every two months, HEPA filters every three to five years, and carbon filters every two years.
STEP 1
Make sure the unit is set to "off" and the unit is unplugged.
Lay the unit upside down, so that the wheels face up.
STEP 2
Using a #2 Philips screwdriver, remove the four screws that hold the base onto the unit.
STEP 3
Grasp the wheels. Remove the base by pulling gently on the wheels
NEW
HEPA
STEP 4
Reach inside the unit, and remove the felt pad.
NEW
CARBON
STEP 5
First, remove the carbon
filter. (pull up gently by placing thumbs on the inner side of the filter)
STEP 6 | STEP 7 | STEP 8 |
Then, remove the HEPA filter | Now, gently insert the new | Then, insert the new |
with the same technique. | HEPA filter. | carbon filter into the unit. |
Step 9
Put back the felt pad removed in STEP 4.
Step 10 | Step 11 | Step 12 |
Replace the base, making sure the | Replace the four screws. | Turn the unit back onto its |
arrow on the gold sticker lines up |
| |
| wheels. It is now ready for use. | |
with unit's rear seam. |
| |
|
|