AllerAir AM000911, N6FMPW001 FILTER ASSEMBLY- Air Medic D, D Models have a 3 deep carbon filter

Models: N6FMPB002 AM000911 A5FMR002 N6FH0411 N6FMPW001

1 4
Download 4 pages 23.66 Kb
Page 3
Image 3
FILTER ASSEMBLY- Air Medic D

FILTER ASSEMBLY- Air Medic D

D Models have a 3" deep carbon filter.

ALLERAIR'S AIR PURIFICATION SYSTEM

LASER TESTED TRUE HEPA

HEPA (Hight Efficiency Particulate Arrestance) filters were develped for the Atomic Energy Commission to remove radio active dust from their laboratories. The are now the primary filtration systems for electonic clean room assembly, hospital surgeries, bio engineering, pharmaceutical laboratories and any other space where clean air is critical.

HEPA will trap microscopic dust which will give you distress from allergies, asthma, respiratory problems, chemical sensitivities and sick building syndrome. It will trap 99.97% of all particles down to 0.3 microns (including bacteria, dust mite antigens, respiratory particles, fungal and other microbiologicals. For these reasons that HEPA filtration is recommended by more allergists, medical professionals and clean air consultants than any other filter system available.

CARBON FILTER (ACTIVATED AND GRANULATED)

Step 1

Turn Power Off and unplug receptacle.

Lay unit upside down.

Step 4

Remove only one of the white, felt, donut-shaped gaskets from the inside of the purifier body.

Step 7

Place lid back to its proper position by aligning the arrow with the rear seam.

Step 2

With a #2 Philips screw driver, remove the four screws from the bottom of the unit.

Step 5

Insert the carbon filter (either a Model 600 D Carbon or a Model 600 DX Carbon) into the unit.

Step 8

Replace the four screws

Step 3

Gently grasp wheels.

Remove base by gently pulling on the wheels.

Step 6

Replace the gasket that had been removed in STEP 4.

Step 9

Turn the unit back onto its wheels. It is now ready for immediate use.

We use only activated granular carbon mixed with zeolite and specially impregnated carbons. We stay away from dust carbon which has been impregnated onto a poly or foam material. This type of carbon filter has to be changed as often as every week to be fully effective. AllerAir's carbon filter can last up to 2 or 3 years and more, depending on the level of toxins in the area.

The activated carbon we use is derived from coconut shell and can adsorb up to 60% of its own weight in toxic gases, fumes and chemicals. These toxic substances make us ill, and are found in every home, office and industry.

OTHER FILTERING SYSTEMS AVAILABLE

Ozone generators, negative ion machines and electrostatically charged units all generate ozone which is a toxic substance. Any unit which provides ozone cannot be recommended by Health and Welfare or by the Lung Association.

AllerAir's units on the other hand do not produce any ozone whatsoever. The latest air purification technology does not add anything to the air (especially impurities like ozone or P.V.C.s). AllerAir's unit scrubs impurities and toxins out of the air.

ENERGY COSTS

We use a high efficiency motor which cost pennies a day to operate in contrast to almost all other manufactures who use the lowest price motor available. One of the reasons we can offer a five year extendible to ten year warranty is because of the sophisticated motor we use. We have spared no effort to give you the most for the least.

ADDITIONAL INFORMATION

The rush of air on "Low", makes less noise which is often used to help people sleep more soundly. Use "High" in work places or home living rooms. Use "Turbo" when you are out of the area for the day or night. The sound you hear from the unit is the sound of the air passing through the vent to achieve a current so that your complete area will receive changes of air.

The air coming out of the unit may feel cool to your hand, but the temperture of the air is actually the same. And AllerAir units are specially designed to have no offgasing because our entire unit housing is made of steel.

IMPORTANT NOTICE

To receive maximum use of HEPA filter media when used in freshly painted room, you should first remove the HEPA filter from the unit to avoid contaminating the HEPA media. Turn unit off and Ungplug unit. Remove bottom screws. Open bottom of unit, Grasp outer filter ring firmly with both hands and remove carefully. Close unit, plug into grounded receptacle then turn on. Replace carbon filter before reinstalling HEPA filter.

Do not allow any object to be stuck or poked into any opening of the unit. Never service the unit before turning unit off and removing electrical plug from the wall receptacle.

AllerAir Industries Inc. Toll free: 1-888-852-8247 / Fax: 1-877-688-2193 www.allerair.com