Installation
5
30°
1
2
|
| 2 |
|
A B C D E F G H I J | K | 1 |
|
|
| 3 |
|
|
| AIR |
|
|
| FLOW |
|
| EXHAUST AIR FLOW | 4 | |
| MAXIMUM LENGTH OF | ||
| DUCT 9.1 m (30 feet) |
| |
|
| EXHAUST |
|
|
| OUTLET |
|
HORIZONTAL EXHAUST INSTALLATION |
| ||
|
|
| H318I |
NOTE: Where the exhaust duct pierces a | 3 | Clearance per Local Codes |
|
combustible wall or ceiling, the opening must be | 4 | No Screen or Cap |
|
sized per local codes. | 5 | Clean Out Cover – Inspect Monthly |
|
Wall
Figure 6
.
2
1
CONNECT TO DRYER
43
VERTICAL EXHAUST INSTALLATION
H319I
1Roof
2Wall
35 cm (2 in.) Minimum
4NOTE: Where the exhaust duct pierces a combustible wall or ceiling, an opening must be sized as shown or per local codes.
WARNING
To reduce the risk of fire and the accumulation of combustion gases, DO NOT exhaust dryer air into a window well, gas vent, chimney or enclosed, unventilated area, such as an attic, wall, ceiling, crawl space under a building or concealed space of a building.
W045
Figure 7
512686 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 13 |