NOTE: When connecting to a gas line, an equipment
1.8m (6 feet) of the dryer. An 1/8 in. NPT pipe plug must be installed as shown for checking inlet pressure. Refer to Figure 8.
1
5
2
3
4
D233I
D233I
1New Stainless Steel Flexible Connector - (Use design CSA certified connector) Use only if allowed by local codes
21/8 in. NPT Pipe Plug
3Equipment Shut Off Valve
4Black Iron Pipe
Shorter than 6.1 m (20 ft.) - 9.5 mm (Use 3/8 in.) pipe
Longer than 6.1 m (20 ft.) - use 12.7 mm (1/2 in.) pipe.
53/8 in. NPT Gas Connection
Figure 8
4.Tighten all connections securely. Turn on gas and check all pipe connections (internal & external) for gas leaks with a
NOTE: The dryer and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 3.45 kPa (1/2 lb./in.2). Refer to Step 8 (Check Heat Source).
L.P. (Liquefied Petroleum) Gas, 93.1 MJ/m3
(2500 Btu/ft3), service must be supplied at 10 ± 1.5 inch water column pressure.
For proper operation at altitudes above 1070 m
(3500 feet) the L.P. gas valve spud orifice size must be reduced to ensure complete combustion. Refer to Table 3.
|
|
|
|
|
| Installation | |
|
|
|
| ||||
| L.P. Altitude Adjustments |
|
| ||||
Altitude |
| Orifice Size |
| Part | |||
m | feet | No. |
| mm | inches |
| No. |
1070 | 3500 | 54 |
| 1.40 | 0.0550 |
| 503785 |
2290 | 7500 | 55 |
| 1.32 | 0.0520 |
| 58755 |
3355 | 11000 | 56 |
| 1.18 | 0.0465 |
| 503786 |
Table 3
NOTE: DO NOT connect the dryer to L.P. Gas Service without converting the gas valve. Install L.P. Gas Conversion Kit 458P3 (available at extra cost).
Step 4: Reverse Door, if Desired
NOTE: Doors with windows cannot be reversed.
The door on this dryer is completely reversible. To reverse door proceed as follows:
1. Remove four hinge attaching screws.
D675I | D675I |
Figure 9
2. Remove all nine screws.
D272P
Figure 10
512686 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 15 |