Installation

After either dryer has operated for approximately five minutes, observe burner flame through lower front panel. Adjust the air shutter to obtain a soft, uniform blue flame. (A lazy, yellow-tipped flame indicates lack of air. A harsh, roaring, very blue flame indicates too much air.) Adjust the air shutter as follows:

1.Loosen the air shutter lockscrew.

2.Turn the air shutter to the left to get a luminous yellow-tipped flame, then turn it back slowly to the right to obtain a steady, soft blue flame.

3.After the air shutter is adjusted for proper flame, tighten the air shutter lockscrew securely.

4.Reinstall the lower front panel.

WARNING

For personal safety, lower front panel must be in place during normal operation.

W046

After either dryer has operated for approximately three minutes, exhaust air or exhaust pipe should be warm.

COIN SLIDE, MDC, AND NETMASTER MODELS THROUGH

 

COIN SLIDE, MDC, AND NETMASTER MODELS

 

SERIAL NO. 0803 AND NONMETERED MODELS

 

STARTING SERIAL NO. 0804

1

2

 

 

2

 

 

1

 

6

 

 

 

 

 

6

 

 

 

3

 

3

 

 

4

 

 

5

 

4

 

 

 

 

 

 

 

 

 

 

 

5

 

 

D700I

 

DRY2235N

1

Closed Position

 

5

3.1 mm (1/8 in.) Pipe Plug

2

Shut-Off Valve Handle

 

 

(For checking manifold pressure)

3

Air Shutter Lockscrew

 

6

Open Position

4Air Shutter

Figure 23

512686

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT