Vending

Table 6 (continued)

Models Starting Serial No. 0909

Cool Down Per Cycle

Cool Down

Switch Number

 

(in minutes)

 

7

 

 

3 (preset at factory)

OFF

 

 

6

ON

 

 

Cycle Reset

Switch Number

8

OFF

ON

Total Cycle Time = Heat Time + Cool Down Time

Table 6

Test Setting

When testing coin slide operation or other troubleshooting, set dipswitch with this shorter cycle:

1.Unplug the machine power cord.

2.Record the machine control dipswitch settings. Then set them all to the off position. Refer to Figure 25.

3.Plug in the machine and initiate a cycle.

NOTE: With all the control dipswitches off, the total cycle time will be four minutes long.

4.Once all the testing is complete, unplug the machine and re-set the dipswitches to their original settings.

5.Plug in the machine.

O 1 2 3 4 5 6 7 8

N

DRY2225P

DRY2225P

Figure 25

512686

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT