Maintenance

1

2

H047I

1Bearing Grease Fitting

2Seal Grease Fitting

Figure 12

2.For 80 pound capacity models only, lubricate bearings and seals each month OR after every 200 hours of operation. Refer to Figure 12.

a.Use a premium-grade lithium-based #2 grease. Never mix two types of grease, such as petroleum and silicone.

b.Pump the grease gun slowly, permitting only the following number of strokes:

Bearing grease fitting, 2 strokes

Seal grease fitting, 1 stroke

NOTE: Do not pump the grease gun until grease comes out of the bearing housing. This can result in overlubrication, causing damage to bearings and seals.

3.Remove back panel and check overflow hose and drain hose for leaks.

4.Unlock the hinged lid and check the supply dispenser hoses and hose connections.

5.Clean inlet hose filter screens:

a.Turn water off and allow valve to cool, if necessary.

b.Unscrew inlet hose and remove filter screen.

c.Clean with soapy water and reinstall. Replace if worn or damaged.

6.Tighten motor mounting bolt locknuts and bearing bolt locknuts. Check to see that the pin is in place.

16

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F232134