Operation
To Program a Short Test Cycle:
1.Unplug machine power cord.
2.Write down machine control dip switch settings,
then set them all to the off position. Refer to Figure 4.
3. Plug machine in and start a cycle.
NOTE: With all control dip switches off, the total cycle time will be 1 minute long.
4. Once all testing is complete, unplug machine and
5. Plug machine in.
Error Codes
WARNING
O 1 2 3 4 5 6 7 8
N
12345678
TMB2216N
Figure 4
•Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the tumbler is properly grounded.
|
| W002 |
|
|
|
|
|
|
Display | Definition | Corrective Action |
|
|
|
| Open thermistor error | ● Check thermistor. Replace if inoperative. |
|
| ● Check wiring diagram between control and |
OP |
| thermistor. Refer to wiring diagram for proper |
|
| wiring. |
|
| ● Check control. Replace if inoperative. |
|
|
|
| Shorted thermistor error | ● Check thermistor. Replace if inoperative. |
SH |
| ● Check wiring between control and thermistor. |
| Refer to wiring diagram for proper wiring. | |
|
| |
|
| ● Check control. Replace if inoperative. |
|
|
|
AF - 1 | Airflow switch closed when cycle | ● Check airflow switch. Replace if inoperative. |
started |
| |
|
| |
|
|
|
AF - 2 | Airflow switch failed to close after | ● Check airflow switch. Replace if inoperative. |
cycle started |
| |
|
| |
|
|
|