Operation

If the computer does not receive a signal that water level has been attained within 30 minutes, it will alternately flash “STOP” and “FILL” and sound the on-board beeper for ten seconds. It will then initiate the stop routine.

Wash

As soon as water level is reached (and any programmed temperature is reached), the displayed time begins counting down at one-second intervals.

Agitation is active during this portion of the segment. There are four different agitation actions available. See the following table for more information.

Agitation Action Options

Display

Description

Percentage

 

 

 

 

27 seconds forward,

 

Ag 1

3 seconds pause,

90%

27 seconds reverse,

 

 

 

3 seconds pause

 

 

 

 

 

10 seconds forward,

 

Ag 2

20 seconds pause,

33%

10 seconds reverse,

 

 

 

20 seconds pause

 

 

 

 

 

3 seconds forward,

 

Ag 3

27 seconds pause,

10%

3 seconds reverse,

 

 

 

27 seconds pause

 

 

 

 

 

4 seconds forward,

 

Ag 4

56 seconds pause,

6.7%

4 seconds reverse,

 

 

 

56 seconds pause

 

 

 

 

If the segment contains a heat step, the machine begins heating after the water has reached the programmed level.

Note: If the water does not reach the programmed temperature in 40 minutes, the computer progresses to the wash step.

Drain

If the cycle program segment calls for a drain, the drain valve will open after the programmed segment time has elapsed. If a spin step follows a drain step, the cylinder will turn counterclockwise (forward) at wash speed while in the drain step.

If the cycle program segment does not call for a drain, the computer moves to the next segment of the cycle program. If the segment is at the end of a cycle program, the computer goes into the stop routine.

If the cycle program segment does not call for a spin, the cylinder will continue to agitate throughout the drain step. When the drain has completed, the computer moves to the next segment of the cycle program. If the segment is at the end of a cycle program, the computer goes into the stop routine.

Note: The machine should drain in 30 seconds. If the machine fails to drain, contact a qualified service technician.

F232072