Programming

Setup Mode (Continued)

To enter SETUP mode, press the Stop key while the display is showing the temperature in the sump. Once in SETUP mode, use the Up or Down key to change the selected option. Use the Start key to accept the selected option and move on to the next one. Press the Stop key to exit SETUP mode.

Degrees Displayed in Fahrenheit or Celsius

This SETUP option affects the programming and display of all temperatures. If “FAr” is selected, all temperatures will display in Fahrenheit. If “CEL” is selected, all temperatures will display in Celsius.

Acceptable ranges for programmable temperatures are 75°F – 200°F or 25°C – 93°C.

Auxiliary Heat

Heat is a dedicated output of the V-computer, which controls an optional heat source. If “nOHt” is selected, the heat output will never energize during a cycle (except briefly in the test cycle to ensure that the output functions properly), regardless of programmed temperature settings. If “HEAt” is selected, the output will energize during a cycle if the three following conditions are true:

lA nonzero heat temperatureis programmed.

lThe computer senses that the present temperature is below the programmed target temperature.

lThere is at least a low water level in the machine.

Note: Do not enable the auxiliary heat SETUP option and disable the temperature-controlled fill option on machines not equipped with auxiliary heat. The machine will pause for 40 minutes during any cycle segment where the fill water temperature does not equal or exceed the programmed value of the heat step.

Supply 5 or Auxiliary Fill

If “SUP5” is selected, the output labeled AF on the solid state output board can be used to control a fifth supply signal. This SETUP option must be selected to program a “SUP5” or a “SUP6” (supply 1 and supply 5 combined) in a cycle step.

If “AFIL” is selected, the output labeled AF can be used to control an auxiliary fill valve. Auxiliary fills can be programmed to low, medium, or high water level. It is also possible to program an overflow (flush) in Prewash. This SETUP option must be selected to program an “AFIL” in a cycle step.

Temperature-Controlled Fill

If “tFIL” is selected, a temperature-controlled fill can be programmed for any segment. This SETUP option must be selected to program a “tFIL” in a cycle step. If “ntFL” is selected, this feature is disabled.

24