Installation/Operation Supplement
Thoroughness of detail must be stressed with all foundation work to ensure a stable unit installation, eliminating possibilities of excessive vibration during extract.
CAUTION
Ensure that the machine is installed on a level floor of sufficient strength and that the recommended clearances for inspection and maintenance are provided. Never allow the inspection and maintenance space to be blocked.
W488
The
The standard installation does not require anchoring unless mandated by state or local codes.
Static and dynamic loads on the floor or foundation are shown in Table 2.
Table 2 can be used as a reference when designing floors and foundations.
Floor Load Data
Model | 18 | 25 | 35 | 55 | 75 | 100 | 135 | 165 |
|
|
|
|
|
|
|
|
|
Static floor | 2.51 kN | 2.63 kN | 4.38 kN | 6.97 kN | 10.3 kN | 16.4 kN | 19.1 kN | 24.49 kN |
load | (546 lb.) | (592 lb.) | (983 lb.) | (1566 lb.) | (2310 lb.) | (3682 lb.) | (4282 lb.) | (5509 lb.) |
|
|
|
|
|
|
|
|
|
Static | 6.79 | 5.17 | 6.53 | 8.33 | 8.97 | 11.5 | 12.5 | 14.84 |
pressure | (137 | (109 | (137 | (175 | (188 | (240 | (261 | (310 |
Dynamic | 0.7 kN | 0.75 kN | 1.2 kN | 1.7 kN | 2.0 kN | 2.96 kN | 3.75 kN | 4.86 kN |
floor load | (157 lb.) | (169 lb.) | (270 lb.) | (382 lb.) | (450 lb.) | (665 lb.) | (883 lb.) | (1093 lb.) |
|
|
|
|
|
|
|
|
|
Maximum | 0.7 kN | 0.75 kN | 1.2 kN | 1.7 kN | 2.0 kN | 2.96 kN | 3.75 kN | 5.78 kN |
dynamic | (157 lb.) | (169 lb.) | (270 lb.) | (382 lb.) | (450 lb.) | (665 lb.) | (883 lb.) | (1301 lb.) |
load |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Dynamic | 1.89 | 1.47 | 1.79 | 2.03 | 7.75 | 2.07 | 2.46 | 3.05 |
pressure | (39.4 | (31.1 | (37.6 | (42.7 | (36.6 | (43.3 | (53.8 | (63.7 |