See Figure 14. Loosen motor mounting bolts and slide motor along motor plate to change belt span length. Belt deflection should be measured as close to the center of the span length as possible. A set force should be applied in the center of the span length, as specified in the table below.
Machine | Deflection | Force Applied | |
Capacity | |||
(in) | (lbs) | ||
(lbs) | |||
|
| ||
|
|
| |
18 | 0.246 | 5.6 | |
|
|
| |
25 | 0.250 | 5.6 | |
|
|
|
Deflection
Span
Length
GV001IE1A
Figure 14
c.Verify that the
Maintenance
Motor
Drive Pulley
Straightedge
Driven
Pulley
GV002BE1A
Figure 15
3.Remove back panel and check overflow hose and drain hose for leaks.
4.Unlock the hinged lid and check the supply dispenser hoses and hose connections.
5.Clean inlet hose filter screen:
a.Turn water off and allow valve to cool, if necessary.
b.Unscrew inlet hose and remove filter screen.
c.Clean with soapy water and reinstall. Replace if worn or damaged.
6.Tighten motor mounting bolt locknuts and bearing bolt locknuts, if necessary.
7.Use compressed air to clean lint from motor.
8.Clean interior of machine, both basket and shell, by wiping with
a
9.Use compressed air to ensure that all electrical components are free of moisture and dust.
F232060 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 35 |