Programming

Cycle Charts for Domestic OPL Models Built Prior to April 2005 (Displays P-F1)

Displays P-F1 after power is applied to machine when START (enter) keypad is pressed while display shows “- - - -”.

Cycle Steps

Normal

Light

Heavy

Stained

Perm

Visa®

Uniforms

Delicate

Hot

Soil

Soil

Hot

Press

Warm

Cold

 

Hot

Hot

Hot

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cycle reference

CY01

CY02

CY03

CY04

CY05

CY06

CY07

CY08

(display in program mode)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Agitation in effect for cycle

12/3/12

12/3/12

12/3/12

12/3/12

12/3/12

12/3/12

12/3/12

3/12/3

 

Normal

Normal

Normal

Normal

Normal

Normal

Normal

Gentle

 

 

 

 

 

 

 

 

 

Wash 1 (WASH indicator)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Time for agitation (min)

2

7

2

4

7

2

2

5

 

 

 

 

 

 

 

 

 

Fill valves (temperature)

Both

Both

Both

Cold

Hot

Both

Both

Cold

 

 

 

 

 

 

 

 

 

Fill water level

High

Low

High

Med

Low

High

High

High

 

 

 

 

 

 

 

 

 

Supply

0

2

0

1

2

0

0

1

 

 

 

 

 

 

 

 

 

Heat (if enabled)

0

0

0

0

0

0

0

0

 

 

 

 

 

 

 

 

 

Drain

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

 

 

 

 

 

 

 

 

 

Spin (only if ‘drain’) seconds

0

0

0

0

0

0

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wash 2 (WASH indicator)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Time for agitation

7

2

7

9

2

7

7

 

 

 

 

 

 

 

 

 

 

Fill valves (temperature)

Hot

Hot

Hot

Hot

Hot

Both

Hot

 

 

 

 

 

 

 

 

 

 

Fill water level

Low

High

Low

Low

High

Low

Low

 

 

 

 

 

 

 

 

 

 

Supply

2

0

1

1

0

1

2

 

 

 

 

 

 

 

 

 

 

Heat (if enabled)

0

0

0

0

0

0

0

 

 

 

 

 

 

 

 

 

 

Drain

No

Yes

Yes

Yes

Yes

Yes

Yes

 

 

 

 

 

 

 

 

 

 

Spin (only if ‘drain’) seconds

0

0

0

0

0

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wash 3 (WASH indicator)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Time for agitation

2

 

6

9

 

7

 

 

 

 

 

 

 

 

 

 

 

Fill valves (temperature)

Hot

 

Hot

Hot

 

Both

 

 

 

 

 

 

 

 

 

 

 

Fill water level

High

 

Low

Low

 

Low

 

 

 

 

 

 

 

 

 

 

 

Supply

0

 

2

2

 

2

 

 

 

 

 

 

 

 

 

 

 

Heat (if enabled)

0

 

0

0

 

2

 

 

 

 

 

 

 

 

 

 

 

Drain

Yes

 

No

No

 

No

 

 

 

 

 

 

 

 

 

 

 

Spin (only if ‘drain’) seconds

0

 

0

0

 

0

 

 

 

 

 

 

 

 

 

 

 

Table 4

F232168

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT