Programming
Cycle Charts for International OPL
Cycle Steps | Normal | Normal | Normal | Gentle | Perm | Perm | Perm | Gentle | |
Press | Press | Press | |||||||
95°C | 60°C | 40°C | Cold | 30°C | |||||
| 95°C | 60°C | 40°C | ||||||
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
| |
Agitation in effect for cycle | 12/3/12 | 12/3/12 | 12/3/12 | 3/12/3 | 12/3/12 | 12/3/12 | 3/12/3 | 3/12/3 | |
| Normal | Normal | Normal | Gentle | Normal | Normal | Gentle | Gentle | |
|
|
|
|
|
|
|
|
| |
Wash 1 (WASH indicator) |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| |
Time for agitation (min) | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | |
|
|
|
|
|
|
|
|
| |
Fill valves (temperature) | Both | Both | Both | Cold | Both | Both | Both | Cold | |
|
|
|
|
|
|
|
|
| |
Fill water level | Low | Low | Low | High | Low | Low | Low | High | |
|
|
|
|
|
|
|
|
| |
Supply | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | |
|
|
|
|
|
|
|
|
| |
Heat (if enabled) | 40c | 40c | 40c | 0 | 40c | 40c | 40c | 0 | |
|
|
|
|
|
|
|
|
| |
Drain | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | |
|
|
|
|
|
|
|
|
| |
Spin (only if ‘drain’) seconds | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| |
Wash 2 (WASH indicator) |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| |
Time for agitation | 6 | 6 | 6 |
| 6 | 6 | 6 | 3 | |
|
|
|
|
|
|
|
|
| |
Fill valves (temperature) | Hot | Both | Both |
| Hot | Both | Both | Cold | |
|
|
|
|
|
|
|
|
| |
Fill water level | Low | Low | Low |
| Low | Low | Low | High | |
|
|
|
|
|
|
|
|
| |
Supply | 2 | 2 | 2 |
| 2 | 2 | 2 | 2 | |
|
|
|
|
|
|
|
|
| |
Heat (if enabled) | 95c | 60c | 40c |
| 95c | 60c | 40c | 30c | |
|
|
|
|
|
|
|
|
| |
Drain | No | No | No |
| No | No | No | Yes | |
|
|
|
|
|
|
|
|
| |
Spin (only if ‘drain’) seconds | 0 | 0 | 0 |
| 0 | 0 | 0 | 0 | |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| |
Wash 3 (WASH indicator) |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| |
Time for agitation | 2 | 2 | 2 |
| 2 | 2 | 2 |
| |
|
|
|
|
|
|
|
|
| |
Fill valves (temperature) | Cold | Cold | Cold |
| Cold | Cold | Cold |
| |
|
|
|
|
|
|
|
|
| |
Fill water level | High | High | High |
| High | High | High |
| |
|
|
|
|
|
|
|
|
| |
Supply | 0 | 0 | 0 |
| 0 | 0 | 0 |
| |
|
|
|
|
|
|
|
|
| |
Heat (if enabled) | No | No | No |
| No | No | No |
| |
|
|
|
|
|
|
|
|
| |
Drain | Yes | Yes | Yes |
| Yes | Yes | Yes |
| |
|
|
|
|
|
|
|
|
| |
Spin (only if ‘drain’) seconds | 0 | 0 | 0 |
| 0 | 0 | 0 |
| |
|
|
|
|
|
|
|
|
|
Table 5 (Continued)
26 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | F232168 |