Patch Release Note

Features in 86251-01

Patch 86251-01 includes the following enhancements:

PCR: 02331

Module: IPG, ETH

Network affecting: No

IP is now informed when an Ethernet interface goes up or down, after a 2.5 second delay.

PCR: 02525

Module: TELNET, PING, IPV6, Network affecting: No

 

TCP

The ADD IPV6 HOST command was not accepting the INTERFACE parameter when adding a host with a link-local address. This issue has been resolved.

PCR: 02527

Module: TCP

Network affecting: No

TCP did not send a TCP Reset message under some circumstances, for example when the Telnet server was disabled. This issue has been resolved.

PCR: 02552

Module: SWI

Network affecting: No

If ingress filtering was supported within trunk groups, ports with ingress filtering enabled were erroneously added to the trunk group. This issue has been resolved.

PCR: 02574 Module: DVMRP

Network affecting: No

Some change actions, and the resending of prune messages were not operating correctly. This issue has been resolved.

PCR: 02581

Module: TM

Network affecting: No

The test facility was not testing switch ports. This issue has been resolved.

Availability

Patches can be downloaded from the Software Updates area of the Allied Telesyn web site at www.alliedtelesyn.co.nz/support/updates/patches.html. A licence or password is not required to use a patch.