CV10x SERIES  Converteon Series Line Card

CV10x SERIES Converteon Series Line Card

Link Test, MissingLink,

and Smart MissingLink Functions

Link Test

The link test is a fast and easy way for you to test the connections between the media converter ports and the end-nodes that are connected to the ports. If a network problem occurs, you can perform a link test to determine which port is experiencing a problem, and so be able to focus your troubleshooting efforts on the cable or end-node where the problem resides.

MissingLink

The MissingLink feature enables the two ports on the media converter to pass the ‘Link’ status of their connections to each other. When the media converter detects a loss of connection to an end-node, the media converter shuts down the connection to the other port, thus notifying the end-node that the connection has been lost.

Smart MissingLink

The Smart MissingLink feature performs exactly the same function as MissingLink with one additional feature. When a link is lost on a port, the LINK LED of the port which still has a valid connection to its end-node starts to blink. This allows you to quickly determine which port still has a valid connection (LINK LED blinking) and which port has lost its connection (LINK LED off).

Technical Specifications

Status Indicators

System LEDs

DIP Switches

The AT-CV102 line card features both the Diagnostic Mode (Table 1) and Port Configuration (Table 2) DIP switches. The tables below list the positions of the DIP switches.

Table 1. Diagnostic Mode DIP Switches Positions

Operating Mode

DIP 1

DIP 2

DIP 3

DIP 4

Link Test (default)

Off

Off

X

X

 

 

 

 

 

Smart MissingLink

Off

On

X

X

(SML)

 

 

 

 

MissingLink (ML)

On

Off

X

X

 

 

 

 

 

Manufacturing

Off

Off

Off

Off

Settings

 

 

 

 

‘X’ means the DIP switch position could be either On or Off.

Table 2 lists the Port Configuration DIP switches positions.

Table 2. Port Configuration DIP Switches Positions

Operating Mode

DIP 1

DIP 2

DIP 3

DIP 4

Auto MDI-X Enabled

X

Off

X

X

(default)

 

 

 

 

Auto MDI-X Disabled

X

Off

X

X

 

 

 

 

 

Manufacturing

Off

Off

Off

Off

Settings

 

 

 

 

‘X’ means the DIP switch position could be either On or Off.

Environmental Specifications Maximum operating temperature: 0°C to 40°C

(32°F to 104°F)

Maximum storage temperature: -25°C to 70°C (-13°F to 158°F)

Operating and storage altitude: Up to 3,048 meters (10,000 feet)

Relative

humidity operating

and

 

storage

(non-condensing):

5% to 95%

Predicted

MTBF (Telcordia SR332):

 

 

 

 

AT-CV101

1,020,000

hrs

 

 

 

AT-CV102

890,000 hrs

 

 

 

AT-CV102/1

1,020,000

hrs

 

 

 

AT-CV102/2

1,020,000

hrs

Standards

 

 

EMI

part

15:

 

 

FCC

class

A, EN55022 class

A, VCCI class A, C-Tick, CE

Immunity:

EN55024

Safety:

UL60950-1 (cULUS), EN60950-1 (TUV)

EN60825

LED

Color

Description

 

 

 

RDY

Green

The line card has passed diagnostics

 

Off

The line card has not passed diagnostics

ML

Green

MissingLink

mode

is

enabled

 

Off

MissingLink

mode

is

disabled

SML

Green

Smart MissingLink mode is enabled

 

Off

Smart MissingLink mode is disabled

Fiber Port LEDs

 

 

 

LED

Color

Description

 

 

 

LK

Green

Link established on the port

 

Off

No link established on the port

AT

Green

TX/RX activity detected on the port

 

Off

No activity detected on the port

Copper Port LEDs

 

 

 

LED

Color

Description

 

 

 

LK

Green

Link established on the port

 

Off

No link established on the port

AT

Green

TX/RX activity detected on the port

 

Off

No activity detected on the port

FD

Green

Port operating in full-duplex mode

 

Off

Port operating in

half-duplex mode

Physical Specifications

Dimensions

2.2cm x 7.3cm x 13cm

(W x D x H)

(0.855” x 2.89” x 5.1”)

Weight

 

0.27kg (0.60lbs)

Optical Characteristics

Connector

type

Dual SC or dual ST

Fiber type

 

Single-mode or multi-mode

Operating

distance

2km (1.24 miles) to 40km (24.8 miles)

Optical Output Power (dBm)

 

Product

Minimum

Maximum

Wavelength

Connector

AT-CV101

-20dBm to -14dBm

1310nm

Dual ST

AT-CV102

-20dBm to -14dBm

1310nm

Dual SC

AT-CV102/1

-15dBm to

-5dBm

1310nm

Dual SC

AT-CV102/2

-15dBm to

0dBm

1310nm

Dual SC

Receiver Power Sensitivity (dBm)

Product Minimum Maximum

AT-CV101 -31dBm to -11dBm

AT-CV102 -31dBm to -11dBm

AT-CV102/1 -34dBm to -3dBm

AT-CV102/2 -34dBm to -3dBm

Power Characteristics

Power consumption

5.7W

Ordering Information

AT-CV101

Fast Ethernet Converteon media converter line card, 100TX to 100FX, MMF, ST, 2km

AT-CV102

Fast Ethernet Converteon media converter line card, 100TX to 100FX, MMF, SC, 2km

AT-CV102/1

Fast Ethernet Converteon media converter line card, 100TX to 100FX, SMF, SC, 15km

AT-CV102/2

Fast Ethernet Converteon media converter line card, 100TX to 100FX, SMF, SC, 40km

USA Headquarters 19800 North Creek Parkway Suite 200 Bothell WA 98011 USA T: +1 800 424 4284 F: +1 425 481 3895

European Headquarters Via Motta 24 6830 Chiasso Switzerland T: +41 91 69769.00 F: +41 91 69769.11

Asia-Pacific Headquarters 11 Tai Seng Link Singapore 534182 T: +65 6383 3832 F: +65 6383 3830

www.alliedtelesis.com

© 2007 Allied Telesis Inc. All rights reserved. Information in this document is subject to change without notice. All company names, logos, and product designs that are trademarks or registered trademarks are the property of their respective owners.

617-000169 Rev E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 2
Image 2
Allied Telesis AT-CV10x Series CV10x SERIES Converteon Series Line Card, Technical Specifications, Ordering Information