Chapter 7: Powering On the Chassis
186
synchronized its database with the active control card, at which point it
turns solid amber to indicate the inactive state of the card. However, the
inactive card is forwarding traffic over the backplane.
Using the ConsolePort to Monitorthe InitializationProcessAnother way to monitor the initialization process of the chassis is to
connect a terminal or PC with a terminal emulator program to the Console
port on the control card and watch the status messages. (The settings for
the terminal or terminal emulator program are found in “Using Local
Management to Verify the Chassis” on page 192.) Figure 142 here and
Figure 143 on page 187 illustrate the messages. The chassis has
completed phase 1 when it displays the “Username” prompt. To monitor
phases 2 and 3, log in to the switch and use the SHOW CARD command.
For instructions, refer to the Software Reference for SwitchBlade x3100
Series Switches.
Figure 142. Switch Initialization Messages
@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@
ATI 200G Central Fabric Controller Boot Loader
Version 15.0.g.03
Created on Fri 01/14/2011 at 11:11 AM
Copyright Allied Telesis Inc., 2009
VxWorks Version 5.5.1 for MV78100 CFC200 LE MMU ARCH 5
BSP version 1.2/1.3.5_000
Copyright Wind River Systems, Inc., 1984-2002
@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@
********************************************************************
* Warning: The password for the bootrom is the system default.
* The password should be changed to avoid a security risk.
********************************************************************
Press ^b to stop automatic loading of software image...
0
Automatically loading software image...
FPGA Version 16.0
Starting Application Software Loading
Attaching to Flash File System ... done.
/tffs/ - Volume is OK
Boot album is (current, attempt 1): 'cfc200_15.1.0.tar'
Checking Album's integrity...done