GE8 AT-TN117-A 8 Port GbE Service and Aggregation Module
Interface Specifications
Number | of | GbE ports: | 8 |
Backplane | capacity: | 10Gbps | |
Physical | design: | Front Access | |
|
|
| 8x SFP |
Port Specifications | |||
Number of VLANs per port: 4095 | |||
Priority | queues: | 8 | |
Dropped | packet counter |
|
Full | traffic | classifier | support |
Full | traffic | classifier | action support |
ARP | Filtering |
|
Egress | Metering: |
| 1Mbps increment | |
Ingress | Max | Burst | Size: | 64kbps |
gress | Max | Burst | Size: | 64kbps |
Protocols and Specifications
IEEE 802.1Q VLAN Bridging
IEEE 802.1p Prioritization
IETF RFC 1112 IP Multicasting/IGMP Snooping v1 IETF RFC 2236 IP Multicasting/IGMP Snooping v2 DHCP Relay Agent option 82 (RFC 3046)
Power Requirements |
| |
Maximum Power: | 53W |
|
Environmental Specifications | ||
Operating Temp: | to 65C | |
Storage Temp: | to 75C | |
Relative Humidity: | 5% | to 95%, |
Regulatory Approvals
FCC Part 15 Class A/ANSI C63.4 |
| ||
EN 300 386 | 55022:1998, Class A | ||
VCCI Class A; ITE/ CISPR 22:1997 Class A | |||
EN 300 386 | 55022:1998, Class A | ||
EN 300 386 | |||
EN 300 | 386 |
| |
EN 300 | 386 | ||
EN 300 | 386 | ||
EN 300 | 386 |
UL/cUL 60950: IEC60950
NEBS Level 3,
USDA RUS
Ordering Information
GE8
Model |
|
|
| Description | Part # |
| |||
|
|
|
|
|
|
|
| ||
GE8 |
|
|
|
| 8 ports, GE8 Service and Aggregation Module |
| |||
|
|
|
|
|
| ||||
|
|
|
|
|
| ||||
iMAP 9x00 Chassis |
|
|
|
| |||||
|
|
|
|
|
|
| |||
Model |
|
|
| Description | Part # |
| |||
|
|
|
|
|
|
| |||
iMAP | 9700 |
|
|
|
| ||||
|
|
|
|
|
|
|
|
| |
iMAP | 9700 |
|
| chassis | with DC power without faceplates |
| |||
|
|
|
|
|
|
|
|
| |
iMAP | 9400 |
|
| chassis | with DC power with faceplates |
|
| ||
|
|
|
|
|
|
|
|
| |
iMAP | 9400 |
|
| chassis | with DC power without faceplates |
| |||
|
|
|
|
|
|
| |||
MiniMAP | 9101 |
|
|
| |||||
|
|
|
|
|
|
| |||
MiniMAP | 9102 |
|
|
| |||||
|
|
|
|
|
| ||||
|
|
|
|
|
| ||||
iMAP Common Control |
|
|
|
| |||||
|
|
|
|
|
|
| |||
Model |
|
|
| Description | Part # |
| |||
|
|
|
|
|
|
|
|
|
|
CFC24 |
|
|
|
| 24GbE | switch | controller card |
| |
|
|
|
|
|
|
|
| ||
GE3 |
|
|
|
| 3x GbE WAN interface card |
| |||
|
|
|
|
|
|
|
| ||
CFC56 |
|
|
|
| 56 GbE switch controller card |
| |||
|
|
|
|
|
|
|
| ||
XE1 |
|
|
|
| 10 GbE WAN interface card |
| |||
|
|
|
|
|
|
|
|
|
|
CFC12 |
|
|
|
| 12GbE | switch | controller card |
| |
|
|
|
| ||||||
|
|
|
| ||||||
Related iMAP Line Cards and Accessories |
|
| |||||||
|
|
|
|
|
|
| |||
Model |
|
|
| Description | Part # |
| |||
|
|
|
|
|
|
|
| ||
FE10 |
|
|
|
|
| ||||
|
|
|
|
|
|
| |||
FX10BX |
|
|
|
|
| ||||
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
*Where | XX | = 10 | for U.S. power cord | = 40 for Australia power cord |
|
| |||
|
|
| = 20 for no power cord | = 50 for Europe power cord |
|
| |||
|
|
| = 30 | for U.K. power cord |
|
|
| ||
|
|
|
|
|
|
|
|
|
|
USA Headquarters 19800 North Creek Parkway Suite 200 Bothell WA 98011 USA T: +1 800 424 4284 F: +1 425 481 3895
European Headquarters Via Motta 24 6830 Chiasso Switzerland T: +41 91 69769.00 F: +41 91 69769.11
www.alliedtelesis.com
© 2006 Allied Telesis Inc. All rights reserved. Information in this document is subject to change without notice. All company names, logos, and product designs that are trademarks or registered trademarks are the property of their respective owners.