B: PREPARING THE SITE

ELECTRICAL POWER REQUIREMENTS

The GS4000 can be ordered for 115 Volts AC (VAC) or 230 VAC operation. The AWG wire size for the electrical service depends on the distance of the operator from the breaker panel. Refer to Table 1 to determine the correct wire size.

The DISTANCE column is the ideal distance from the breaker panel

110112

 

AC POWER SOURCE

 

 

 

 

 

 

TYPICAL CONNECTIONS

 

 

 

SINGLE GATE

DOUBLE GATE

HIGH VOLTAGE TERMINALS

 

 

 

WIRE

 

WIRE

 

 

 

 

SIZE

DISTANCE

SIZE

DISTANCE

GND

L2

L1

 

 

 

 

#14

100 FT

#14

50 FT

 

 

 

#12

150 FT

#12

75 FT

 

 

 

#10

250 FT

#10

125 FT

 

 

 

#8

400 FT

#8

200 FT

 

 

 

#6

600 FT

#6

300 FT

 

 

 

NOTE: DISTANCE IS TOTAL LENGTH OF

120 VAC, 15A

WIRE FROM CIRCUIT BREAKER IN THE

Dedicated Circuit

MAIN PANEL TO THE GATE OPERATOR.

 

Table 1

to the operator for a given wire size and voltage.

NOTE! FOR A BI-PARTING INSTALLATION, THERE WILL BE TWO MECHANICAL UNITS OPERATING AT THE SAME TIME. IT WILL BE NECESSARY TO REDUCE THE LENGTHS IN TABLE 1 BY A FACTOR OF TWO.

Class 2 low voltage wiring from external controls such as a key pad, card reader, telephone entry device, etc. must be brought to the GS4000 CONTROL BOX by a separate conduit from the 115 VAC electrical hook up conduit. Low voltage control wires MUST NEVER be routed in the same conduit as the HIGH VOLTAGE power wires.

Note! The limit switch wires from the GS4000 CONTROL BOX to the GS4000 MECHANICAL UNIT ARE LOW VOLTAGE WIRES AND MUST BE ROUTED IN A LOW VOLTAGE CONDUIT TO THE CONTROL BOX.

WARNING!

AVOID ELECTROCUTION:

DO NOT ROUTE LOW VOLTAGE WIRES IN SAME CONDUIT AS HIGH VOLTAGE WIRES. FOLLOW ALL LOCAL ELECTRICAL CODES OR THE NATIONAL ELECTRICAL CODE.

OTHER VOLTAGES AND 3 PHASE SYSTEMS.

The GS4000 can operate at other voltages or on three (3) phase systems. To operate at 440 VAC it will be necessary to install an external step down transformer. The transformer should be located in a separate electrical box and protected by suitable circuit breaker and/or fusing. A 440 Volt rated switch should also be installed. Follow local electrical codes or the National Electrical Code. The transformer selected should be UL LISTED and be rated for a minimum 700 Volt-Amperes (Watts).

IF TWO MECHANICAL UNITS ARE TO BE USED FOR A BI- PARTING GATE SYSTEM, THEN A 1000 VOLT-AMPERE/ WATT TRANSFORMER MUST BE USED.

Operating from a three (3) phase line will require the use of a 230 VAC rated GS4000. The GS4000 may be operated from a 230 Volt "Delta" line or a 120/208 "Y" line. In either case, ONLY one "leg" of the three phase line will be used. The unbalance of the line will be minimal since the full rate current of the GS4000 at 220 VAC is only

2.2amperes. (4.4 Amperes for a bi-parting system.) Connect any two wires of the three phase system to the 230 VAC GS4000 Tape the third wire carefully so that it does not short to any other object. (The "Y" system will have 4 wires, one of which will be the "common". Make sure the common is NOT selected as one of the wires connected to the GS4000.) It is always best to also pull a ground wire from the electrical service box to the GS4000 to ensure the frame is securely affixed to GROUND.

SERVICE CONDUIT

For new installations the conduit for the High Voltage may be brought to a junction box near where the GS4000 CONTROL BOX will be located or it may be brought directly to the Control Box.

104952

Figure 8: Service Conduits

8

Page 8
Image 8
Allstar Products Group ANSI/UL 325 Electrical Power Requirements, Other Voltages and 3 Phase Systems, Service Conduit

ANSI/UL 325 specifications

Allstar Products Group is a prominent manufacturer in the realm of access control and safety products, and its commitment to quality is evidenced by its compliance with ANSI/UL 325 standards. These standards are essential for ensuring the safety and reliability of automatic gates and their related components, focusing on minimizing risks associated with entrapment and injury.

One of the key features of Allstar's ANSI/UL 325 compliant products is their advanced safety mechanisms. These include integrated sensing technology that detects the presence of objects or obstacles in the path of the gate, effectively preventing accidents. This safety technology often encompasses features such as photo eyes and edge sensors that can immediately halt or reverse the movement of a gate if an obstruction is detected.

Additionally, Allstar’s product range is notable for its robust design and durability. Built to withstand various environmental conditions, these products use high-quality materials that ensure longevity and reliability, meeting the stringent demands of both residential and commercial applications. The designs are also forward-thinking, incorporating user-friendly features that allow for easy installation and maintenance.

Another characteristic that sets Allstar apart is their integration of advanced technologies. Many of their products support smart technology, enabling users to control their gates through mobile applications or remote access systems. This integration allows for convenience and enhanced security, providing real-time alerts and status updates.

Allstar Products Group also emphasizes compliance to facilitate peace of mind for users. All their ANSI/UL 325 certified products undergo rigorous testing procedures to ensure they meet the stringent safety and performance requirements set forth by the American National Standards Institute and Underwriters Laboratories. This adherence to such standards not only assures consumers of reliability but also aligns with the industry’s best practices.

In conclusion, Allstar Products Group’s ANSI/UL 325 compliant products exemplify cutting-edge safety features, robust construction, and advanced technology integration. Their commitment to quality and safety ensures that customers can enjoy the benefits of automatic gate systems with confidence, knowing that they adhere to the highest safety standards in the industry.