AltiGen comm manual TRITON T1 BOARD, Qu I C K In S Ta L L At I O N Gu I D E, LED Indicators

Models: T1

1 4
Download 4 pages 62.24 Kb
Page 1
Image 1
TRITON T1 BOARD

TRITON T1 BOARD

QU I C K IN S TA L L AT I O N GU I D E

MVIP BUS

MVIP Connector

System

Termination Switch

 

Configuration Switch

TRITON T1 BOARD

The Triton T1 Board uses the following signaling and framing features:

Signaling: loop start, ground start, E&M immediate start, E&M wink start*

Line Encoding: AMI, B8ZS*

*recommended

MINIMUM SYSTEM REQUIREMENTS:

IBM/PC AT compatible system with adequate number of full-size ISA and PCI slots

233 Mhz Pentium processor (or better)

2 - 4 GB Hard Disk Drive Space (depending on voicemail requirements)

Windows NT Server 4.0 with Service Pack 4 (or higher) installed

128 MB RAM

AltiGen’s Quantum Telephony Board (one or more, Rev. D or higher)

AltiGen’s Triton T1 Board (one or more)

AltiWare OE R3.0 (or higher)

300W/10A CPU Power (minimum required to power AltiGen boards only)

CSU (Channel Service Unit)

# of AltiGen Boards
# of Slots**

CPU

HDD

 

 

 

 

 

1 Triton T1, 1-3 Quantum

2 PCI, 3 ISA

233 Mhz

2GB

 

 

 

 

 

1 Triton T1, 1-6 Quantum

2 PCI, 6 ISA

300 Mhz

2GB

 

 

 

 

1-4 Triton T1, 1-10 Quantum

5 PCI, 10 ISA

350 Mhz

4GB

 

 

 

 

 

 

# of AltiGen Boards

Power Supply**
Typical Power Supply

 

 

 

 

 

1 Triton T1, 1-3 Quantum

+12V: 4.2

Amps +5V: 6Amps

300W/30A@5V/12A@12V

 

 

 

 

 

1 Triton T1, 1-6 Quantum

+12V: 8.4

Amps +5V: 10.8Amps

400W/40A@5V/16A@12V

 

 

 

1-4 Triton T1, 1-10 Quantum

+12V: 14 Amps +5V: 21Amps

400W/40A@5V/16A@12V

 

 

 

 

 

 

**The above system requirements are for AltiGen components only, and do not take into account requirements for other system components such as motherboard, disk drives, etc.

LED Indicators

GREEN LED
RED LED
Status

 

 

 

OFF

OFF

No power

ON

OFF

Normal operation

OFF

ON

No signal

ON

Flashing

Faulty signal with frame synchronization***

OFF

Flashing

Faulty signal without frame synchronization

Alternating

Alternating

Frame slips in normal operation

*** Faulty signals include the following: yellow alarm, bipolar violation or frame error

Page 1
Image 1
AltiGen comm manual TRITON T1 BOARD, Qu I C K In S Ta L L At I O N Gu I D E, Minimum System Requirements, # of Slots