Altinex Frequently Asked Questions, Troubleshooting Guide, DA1206RM?, Distribution Amplifiers

Models: DA1206RM

1 9
Download 9 pages 33.01 Kb
Page 8
Image 8
FREQUENTLY ASKED QUESTIONS

DISTRIBUTION AMPLIFIERS

FREQUENTLY ASKED QUESTIONS

9

have when the Video Level

approximately a 35% increase in the video signal

No: DA1206RM?TROUBLESHOOTING GUIDE Question

1

What is a

 

Distribution

 

Amplifier?

 

 

2

When should I

 

use the

Answer

A Distribution Amplifier is a device that allows you to connect a single video source to multiple display devices, such as monitors or projectors used in presentation applications.

In some cases, you need a non-simultaneous

switch is set in the 1.0V output position?

level. This can be used in installations where cable runs exceed 150 feet. It is not recommended that this switch be set in the 1.0V position for shorter cable lengths as the increased level may reduce the life of CRT displays if they are overdriven.

 

DA1206RM?

 

 

3

Which signal

 

formats can be

 

passed

 

through the

 

DA1206RM?

 

 

4

When should I

 

use “+”

 

position of

 

Sync Polarity

 

switch?

 

 

5When should I use the Sync Level switch?

6

What should I

connection of a single C- Video source or a single S- Video source to as many as six different display or recording devices.

The DA1206RM can pass RGBS, RGsB, Component Video (Y, R-Y, B-Y), S- Video (Y/C), and Composite Video by using the appropriate analog channels (Red, Green, Blue).

By setting sync polarity switch to (+) the signal is processed as unchanged and the sync polarity of the output signal is matched with the sync polarity of the unit. By setting the sync polarity to (-) the sync polarity of the output is changed to the opposite of the input.

The SYNC LEVEL switch has two positions 2V and 4V. Most often a 4V Sync Level is used. This should be considered as the default setting. The 2V setting allows compatibility with some older equipment that would be overdriven if stronger signal is used.

This provides

TROUBLESHOOTING GUIDE

10

We have carefully tested and have found no problems in the supplied DA1206RM unit; however, we would like to offer the following suggestions:

Please make sure that the input amplitude levels are as follows.

1.Analog signal is less than 1.5V.

2.Sync signal is less is than 0.3V.

Please check the settings of the Sync level, the Video level, and the Sync Polarity Switches.

Please make sure that the proper quality of cables is used. We recommend Altinex made cables for best results.

If a problem arises after continuous usage at higher voltage, higher temperature, higher humidity, or at other extreme environmental conditions, please correct the problem.

7

Page 8
Image 8
Altinex manual Frequently Asked Questions, Troubleshooting Guide, DA1206RM?, Distribution Amplifiers