Altinex DA1222AT manual Application Diagram, Power Requirements, Mounting Capability

Models: DA1222AT

1 9
Download 9 pages 51.23 Kb
Page 6
Image 6
4.1 POWER REQUIREMENTS

DISTRIBUTION AMPLIFIERS

4.1 POWER REQUIREMENTS

The DA1222AT may be used with either 90- 140V AC or 200-240V AC for the input for ease of use throughout the world. Always make sure that the fuse box window located above the power input connector displays the proper voltage of the country where it is being used. To change the setting first, unplug theDA1222AT, and then squeeze the clips on either side of the fuse box. Pull out the fuse holder and turn it 180 degrees. Reset the fuse holder into fuse box so that proper voltage is being displayed through the window. Re-insert the fuse box making sure that the side clips of the fuse box lock securely into place.

4.2 MOUNTING CAPABILITY

The DA1222AT can be easily mounted into an equipment rack. Four mounting holes are provided on each side of the unit. To mount a single unit, use Altinex 19”-1U Rack Mount Ears (part # DA1294FC). To mount two units in tandem, use an Altinex 19”-1U Rack Mount Shelf (part # DA1293FC). For mounting under the table, optional brackets, such as theTM1271, TM1272, TM1273, or TM1274 can be used.

APPLICATION DIAGRAM

5

5

Page 6
Image 6
Altinex DA1222AT manual Application Diagram, Power Requirements, Mounting Capability, Distribution Amplifiers