Altinex manual INSTALLING YOUR MT103-115, Operation, Troubleshooting Guide, Multi-Tasker

Models: MT103-115

1 8
Download 8 pages 28.62 Kb
Page 7
Image 7
INSTALLING YOUR MT103-115

MULTI-TASKER™

INSTALLING YOUR MT103-115

6

Step 1. Turn OFF the power to the Multi-Tasker™ enclosure.

Step 2. Slide the MT103-115into an available slot in the Multi-Tasker™. Make sure the card fits into place. Secure the card by tightening the retainer screws located on the top and bottom of the card.

Step 3. Turn ON the power to the Multi-Tasker™ enclosure.

Step 4. The LED on the card panel will turn RED indicating that the card is in full operation.

Step 5. Connect a VGA cable from the video source to the MT103-115input connector.

Step 6. The power LED will turn GREEN, indicating an input signal is present.

Step 7. Connect the MT103-115output connector to the Receiver (MT103-116) thru a CAT-5 cable.

OPERATION

7

There is only one adjustment necessary to operate the MT103-115. The adjustment is for equalization on long cable runs. It is adjustable according to the cable length.

The unit will operate successfully as long as cables are attached properly and other technical specifications are followed.

TROUBLESHOOTING GUIDE

8

We have carefully tested and have found no problems in the supplied MT103-115; however, we would like to offer suggestions for the following:

7.1 LED IS NOT LIT

Cause 1: Card cage is not plugged in.

Solution: Plug in the card cage. If the LED turns ON, the problem is solved. If not, see Cause 2.

Cause 2: Card is not plugged in all the way.

Solution: Push the card in all the way. If the LED is still not lit, see Cause 3.

Cause 3: Card cage slot has a problem.

Solution 1: Test the card in other slots. If other slots work, the problem is the card cage slot. The card cage may require service. Call ALTINEX at

(714)990-2300. If the other slots do not work, see Solution 2.

Solution 2: Take any other known good card with an LED and verify that the slot used is good by seeing if the other card’s LED lights in that slot. If it lights, then the original card may be the source of the problem. Call ALTINEX at (714) 990-2300.

7.2 NO DISPLAY

Cause 1: The source has a problem.

Solution: Check the source and make sure that there is a signal present and all source connections are correct. If the source is working and there is still no display, see Cause 2.

Cause 2: Cable connections are incorrect.

Solution: Make sure the cables are connected properly. Also, make sure the continuity and wiring are good. If there is still no display, see Cause 3.

Cause 3: The display has a problem.

Solution: Make sure that the display is powered. If there is still no display, call ALTINEX at (714) 990-2300.

400-0182-003

6

Page 7
Image 7
Altinex INSTALLING YOUR MT103-115, Operation, Troubleshooting Guide, LED IS NOT LIT Cause 1 Card cage is not plugged in