42
GME8
B
LOWER
P
ERFORMANCE
D
ATA
Tons A C
at 0.5" 0.6 0.7 0.8
ESP CFM RISE CFM RISE CFM RI SE CFM RISE CFM RISE CFM CFM CFM
T1 - YEL LOW 1.5 87 5 - --- 79 3 -- -- 7 36 ---- 674 ---- 592 -- -- 5 56 509 46 0
T2 - RED 2.0 103 2 43 965 46 9 14 49 861 ---- 810 ---- 756 71 2 659
T3 - ORANGE 2.5 121737115339109840105142100944 964918877
T4 - BLUE 3.0 136533131334126835122136117238112910861054
T5 - BLACK 3.5 154929150530146030142031137832135013051268
T1 - YELLOW 2.5 126847119849115151109254104157988932883
T2 - RED 3.0 136244130545126147121249117051112110741021
T3 - ORANGE 3.5 157638151939147340142642139842134112901252
T4 - BLUE 4.0 1755----171135165736162736157938154815021463
T5 - BLACK 5.0 2183 ---- 2128 ---- 2094 ---- 2060 ---- 2014 ---- 1992 1944 1847
T1 - YELLOW 3.0 146651141552135755130657124859120211441088
T2 - RED 3.5 164245159646155248149949144951138813521306
T3 - ORANGE 4.0 175042175042170743166744161046157415311486
T4 - BLUE 4.0 187040180541178242173743170144165616061571
T5 - BLACK 5 .0 229 7 ---- 2297 ---- 2224 ---- 210 6 35 2014 37 1896 18 13 166 9
Notes:
(CFM & Temperature Rise vs. External Static Pressure)
0.1 0.2 0.3 0.4 0.5
Model
Heating Speed
As Shipped
Motor Speed
EXTERNAL ST ATIC PRESSU RE (Inches Wa ter Column)
GME81005C***
• CFM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer. If the furnace r equir es two
return filters, this chart assumes both filters are installed.
• All furnaces ship as high-speed cooling and medium-speed heating. Installer must adjust blower cooling and heating speed as needed.
GME80603B***
GME80805C***
• For m ost job s, ab out 375 - 400 CF M per t on whe n cool ing is d esira ble.
• Temperature rise data is based on 2nd-stage heat. First-stage heat is 75% of rise indicated above.
• INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE.
• This chart is for information only. For satisfactory operation, external static pressure should no t exce ed va lue sh own on t he rat ing pla te.
• The above chart is for U.S. furnaces installed at 0-2000 feet. At higher altitudes, a properly derated unit will have approximately the same
temperature rise at a particular CFM, while ESP at the CFM will be lower.
• Factory Motor Speed Setting: T1 = 1st Stage Ht, T2 = 2nd Stage Ht, T5 = Cooling.