Accessibility Clearances (Minimum)

Accessibility Clearances (Minimum)

High Altitude InstallationsIMPORTANT NOTES: WARNING

To avoid death, personal injury or property damage due to fire, clearances to combus- tible surfaces listed as below must be observed.

36 inches front clearance is required for servicing or clean- ing.

NOTE: In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.

CLEARANCES TO COMBUSTIBLE SURFACES

GUD_ MODEL FURNACES (Inches)

FRONT

3

TOP

1

 

 

 

 

RIGHT

1

FLUE

0

 

 

 

 

LEFT

1

FLOOR

C

 

 

 

 

REAR

0

----

----

C = If placed on combustible floor, floor MUST be wood only.

High Altitude Installations

For installations above 4000 feet, please refer to your Amana distributor for required kit(s).

Gas

Altitude

Kit

Orifice

Manifold

Pressure

 

 

 

 

Natural

0-4000 Ft.

None

#43

3.5" W.C.

Propane

0-4500 Ft.

LPTK09

#55

10.0" W.C.

NOTE: In Canada, gas furnaces are certified to 4,500 feet only.

IMPORTANT NOTES:

1.All furnaces have a redundant gas valve and blower door interlock switch.

2.All furnaces are manufactured for use on 115 VAC, 60 Hz, single phase electrical supply.

3.IMPORTANT: While the data is presented as a guide, it is very important to properly size fuses and wires and make electrical connections in accordance with the National Electrical Code and/or all existing local codes.

4.Performance figures are based on Department of En- ergy information and requirements under continuous operating conditions. Performance will vary with weather conditions and use.

5.Drain connections must conform to local codes.

6.Installer must supply the following gas line fittings according to which entrance is used:

Top

Two 90° Elbows

 

One Close Nipple

Left

One 90° Elbow

Right

One 90° Elbow

 

One 45° Elbow

 

One Close Nipple

Flame Sensor

Flame sensor output is 1 to 4 microamps at 115 volts.

Filters

Side Return Filters

Minimum Recommended Size

Size_Air Flow

Disposable*

Permanent*

045_30

1 - 24x24 (576)

1 - 16x25 (280)

070_30

1 - 24x24 (576)

1 - 16x25 (280)

070_40

2 - 16x25 (768)

1 - 16x25 (372)

090_35

2 - 14x25 (692)

1 - 16x25 (342)

090_50

2 - 20x25 (960)

2 - 16x25 (465)

115_50

2 - 20x25 (960)

2 - 16x25 (465)

 

 

 

*Quantity - Inches (Total Minimum Surface Area in Square Inches) Permanent filter sizes are as shipped with furnace. The minimum permanent filter size area is based on allowable face velocity of 620 feet per minute.

Bottom Return Filter Sizes

Model

Filter Size (Inches)

Type

45

14 x 25 x 1

P

70

16 x 25 x 1*

P

90

20 x 25 x 1

P

115

20 x 25 x 1

P

 

 

 

P = Permanent

* As Shipped With Furnace

The figure below shows how the filter is retained over the bottom return air opening.

Filter Retainer

Filter

Furnace Bottom

Filter Retainer

3