Electric Dryer
PRODUCT MODEL NUMBERS
PRODUCT DIMENSIONS
NED4500V NED5400T
NED5100T NED5500T
NED5200T NED5800T
NED5240T NED4800V
Electrical: To supply the required three- or four- wire,
43³⁄₈"
A. Small Opening (110cm) Side-Swing Door
B. Large Opening
*26" (66cm)
15¹⁄₄" |
| 22³⁄₄" | |
43³⁄₈" | (57.8cm) | ||
(38.74cm) | |||
| (110cm) |
| |
| *27³⁄₄" |
| |
| (70.5cm) |
| |
29" |
| 29" | |
(73.66cm) |
| (73.66cm) |
AB
Exhaust venting: Exhaust your dryer to the outside.
C. Wide Opening | 43 ³⁄₈" |
| (110cm) |
D. Wide Opening
Hamper Door
*27³⁄₄"
(70.5cm)
22³⁄₄"
(57.8cm) 43³⁄₈"
(110cm)
*27³⁄₄"
(70.5cm)
29"
(73.66cm)
13³⁄₄" (34.9cm)
29"
(73.66cm)
CD
*Most installations require a minimum 5" (12.7 cm) clearance behind the dryer for exhaust vent with elbow.
RECESSED AREA AND CLOSET INSTALLATION
EXHAUST VENTING
Box hood style
4"
(10.2 cm)
4" | 4" | |
(10.2 cm) | ||
(10.2 cm) | ||
|
Louvered style
For closet installation with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent air openings are acceptable.
18"* |
|
|
(45.7 cm) |
|
|
1" | 29" | 1" |
(2.5 cm) | (73.66 cm) | (2.5 cm) |
| A |
|
| 14"max.* | 48 in.2 | * | |
| (35.6cm) | |||
|
|
| (310 cm2 ) | |
|
|
| 24 in.2 | * |
|
|
| (155 cm2 ) | |
1"* | 27¾" | 5"* |
|
|
(2.5 cm) | (70.5 cm) | (12.7 cm) |
| |
| B |
|
| C |
3"* (7.6 cm)
3"* (7.6 cm)
2.5"
(6.4 cm)
Angled style
Vent System Chart
NOTE: Side and bottom exhaust installations have a 90° turn inside the dryer. To determine maximum exhaust length, add one 90° turn to the chart.
Number of | Type of | Box or | Angled |
90° turns | vent | Louvered | hoods |
or elbows |
| hoods |
|
|
|
|
|
0 | Rigid metal | 64 ft (20 m) | 58 ft (17.7 m) |
| Flexible metal | 36 ft (11 m) | 28 ft (8.5 m) |
|
|
|
|
1 | Rigid metal | 54 ft (16.5 m) | 48 ft (14.6 m) |
| Flexible metal | 31 ft (9.4 m) | 23 ft (7 m) |
|
|
|
|
2 | Rigid metal | 44 ft (13.4 m) | 38 ft (11.6 m) |
| Flexible metal | 27 ft (8.2 m) | 19 ft (5.8 m) |
|
|
|
|
3 | Rigid metal | 35 ft (10.7 m) | 29 ft (8.8 m) |
| Flexible metal | 25 ft (7.6 m) | 17 ft (5.2 m) |
|
|
|
|
4 | Rigid metal | 27 ft (8.2 m) | 21 ft (6.4 m) |
| Flexible metal | 23 ft (7 m) | 15 ft (4.6 m) |
A. Recessed area |
|
B. Side view - closet or confined area |
|
C. Closet door with vents | *Required spacing |
1.Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest number of elbows and turns. When using elbows or making turns, allow as much room as possible. Bend vent gradually to avoid kinking. Use the fewest 90° turns possible.
2.Determine vent length.
The maximum length of the exhaust system depends upon:
•The type of vent (rigid metal or flexible metal).
•The number of elbows used.
•Type of hood.
See the exhaust vent length chart that matches your hood type for the maximum vent lengths you can use.
3. Determine the number of elbows you will need.
IMPORTANT: Do not use vent runs longer than specified in the Vent Length Chart.
In the column listing the type of metal vent you are using (rigid metal or flexible metal), find the maximum length of metal vent on the same line as the number of elbows.
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation | Ref. W10150612 |
Instructions packed with product. Specifications subject to change without notice. |