Amana NED5100T, NED5240T dimensions Electric Dryer, Product Model Numbers Product Dimensions

Models: NED5400T NED5100T NED4500V NED5200T NED5800T NED4800V NED5500T NED5240T

1 1
Download 1 pages 37.12 Kb
Page 1
Image 1

®

Electric Dryer

PRODUCT MODEL NUMBERS

PRODUCT DIMENSIONS

NED4500V NED5400T

NED5100T NED5500T

NED5200T NED5800T

NED5240T NED4800V

Electrical: To supply the required three- or four- wire, single-phase, 120/240-volt, 60-Hz, AC-only electrical supply (or three- or four-wire, 120/208-volt electrical supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit.

43³⁄₈"

A. Small Opening (110cm) Side-Swing Door

B. Large Opening

Side-Swing Door

*26" (66cm)

15¹⁄₄"

 

22³⁄₄"

43³⁄₈"

(57.8cm)

(38.74cm)

 

(110cm)

 

 

*27³⁄₄"

 

 

(70.5cm)

 

29"

 

29"

(73.66cm)

 

(73.66cm)

AB

Exhaust venting: Exhaust your dryer to the outside. Four-inch diameter vent is required. Rigid or flexible metal exhaust vent must be used. Do Not use plastic or metal foil vent. Exhaust outlet hood must be at least 12" (30.5 cm) from the ground or any object that may be in the path of the exhaust.

C. Wide Opening

43 ³⁄₈"

Side-Swing Door

(110cm)

D. Wide Opening

Hamper Door

*27³⁄₄"

(70.5cm)

22³⁄₄"

(57.8cm) 43³⁄₈"

(110cm)

*27³⁄₄"

(70.5cm)

29"

(73.66cm)

13³⁄₄" (34.9cm)

29"

(73.66cm)

CD

*Most installations require a minimum 5" (12.7 cm) clearance behind the dryer for exhaust vent with elbow.

RECESSED AREA AND CLOSET INSTALLATION

EXHAUST VENTING

Box hood style

4"

(10.2 cm)

4"

4"

(10.2 cm)

(10.2 cm)

 

Louvered style

For closet installation with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent air openings are acceptable.

18"*

 

 

(45.7 cm)

 

 

1"

29"

1"

(2.5 cm)

(73.66 cm)

(2.5 cm)

 

A

 

 

14"max.*

48 in.2

*

 

(35.6cm)

 

 

 

(310 cm2 )

 

 

 

24 in.2

*

 

 

 

(155 cm2 )

1"*

27¾"

5"*

 

 

(2.5 cm)

(70.5 cm)

(12.7 cm)

 

 

B

 

 

C

3"* (7.6 cm)

3"* (7.6 cm)

2.5"

(6.4 cm)

Angled style

Vent System Chart

NOTE: Side and bottom exhaust installations have a 90° turn inside the dryer. To determine maximum exhaust length, add one 90° turn to the chart.

Number of

Type of

Box or

Angled

90° turns

vent

Louvered

hoods

or elbows

 

hoods

 

 

 

 

 

0

Rigid metal

64 ft (20 m)

58 ft (17.7 m)

 

Flexible metal

36 ft (11 m)

28 ft (8.5 m)

 

 

 

 

1

Rigid metal

54 ft (16.5 m)

48 ft (14.6 m)

 

Flexible metal

31 ft (9.4 m)

23 ft (7 m)

 

 

 

 

2

Rigid metal

44 ft (13.4 m)

38 ft (11.6 m)

 

Flexible metal

27 ft (8.2 m)

19 ft (5.8 m)

 

 

 

 

3

Rigid metal

35 ft (10.7 m)

29 ft (8.8 m)

 

Flexible metal

25 ft (7.6 m)

17 ft (5.2 m)

 

 

 

 

4

Rigid metal

27 ft (8.2 m)

21 ft (6.4 m)

 

Flexible metal

23 ft (7 m)

15 ft (4.6 m)

A. Recessed area

 

B. Side view - closet or confined area

 

C. Closet door with vents

*Required spacing

1.Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest number of elbows and turns. When using elbows or making turns, allow as much room as possible. Bend vent gradually to avoid kinking. Use the fewest 90° turns possible.

2.Determine vent length.

The maximum length of the exhaust system depends upon:

The type of vent (rigid metal or flexible metal).

The number of elbows used.

Type of hood.

See the exhaust vent length chart that matches your hood type for the maximum vent lengths you can use.

3. Determine the number of elbows you will need.

IMPORTANT: Do not use vent runs longer than specified in the Vent Length Chart.

In the column listing the type of metal vent you are using (rigid metal or flexible metal), find the maximum length of metal vent on the same line as the number of elbows.

Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation

Ref. W10150612

Instructions packed with product. Specifications subject to change without notice.

09-05-08

Page 1
Image 1
Amana NED5100T, NED5240T, NED4500V dimensions Electric Dryer, Product Model Numbers Product Dimensions, Vent System Chart