Venting Requirements

WARNING

Fire Hazard

Use a heavy metal vent. Do not use a plastic vent. Do not use a metal foil vent.

Failure to follow these instructions can result in death or fire.

WARNING: To reduce the risk of fire, this dryer MUST BE EXHAUSTED OUTDOORS.

IMPORTANT: Observe all governing codes and ordinances.

The dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling, attic, crawlspace, or a concealed space of a building.

If using an existing vent system

Clean lint from the entire length of the system and make sure exhaust hood is not plugged with lint.

Replace any plastic or metal foil vent with rigid or flexible heavy metal vent.

Review Vent system chart. Modify existing vent system if necessary to achieve the best drying performance. Only rigid or flexible metal vent shall be used for exhausting.

If this is a new vent system

Vent material

Use a heavy metal vent. Do not use plastic or metal foil vent.

4" (102 mm) heavy metal exhaust vent and clamps must be used. DURASAFE™ venting products are recommended.

4"

102 mm

4" (102 mm) heavy metal exhaust vent

DURASAFE™ vent products can be purchased from your dealer or by calling the toll-free number listed on the cover of the Dryer User Instructions. For more information, see the “Assistance or Service” section of the Dryer User Instructions.

Rigid metal vent

For best drying performance, rigid metal vents are recommended.

Rigid metal vent is recommended to avoid crushing and kinking.

Flexible metal vent

Flexible metal vents are acceptable only if accessible for cleaning.

Flexible metal vent must be fully extended and supported when the dryer is in its final location.

Remove excess flexible metal vent to avoid sagging and kinking that may result in reduced airflow and poor performance.

Do not install flexible metal vent in enclosed walls, ceilings, or floors.

The total length of flexible metal vent should not exceed 734 ft (2.4 m).

Elbows

45° elbows provide better airflow than 90° elbows.

GoodBetter

Clamps

Use clamps to seal all joints.

Exhaust vent must not be connected or secured with screws or other fastening devices that extend into the interior of the duct and catch lint. Do not use duct tape.

Clamp

Exhaust

Recommended hood styles are shown here.

B

A

4"

(102 mm)

4" (102 mm)

A. Louvered hood style

B. Box hood style

The angled hood style (shown here) is acceptable.

4"

(102 mm)

2½" (64 mm)

11

Page 11
Image 11
Amana W10150613B Venting Requirements, If using an existing vent system, If this is a new vent system Vent material