Amana W10216187A Optional exhaust installations, Alternate installations for close clearances

Models: W10216187A

1 24
Download 24 pages 63.3 Kb
Page 10
Image 10

Optional exhaust installations

This dryer can be converted to exhaust out the right side, left side, or through the bottom. Contact your local dealer to have the dryer converted.

Part Number 4396011 - 18" (457.2 mm) to 29" (736.6 mm) mismatch

Part Number 4396014 - 29" (736.6 mm) to 50" (1270 mm) mismatch

WARNING

Fire Hazard

Cover unused exhaust holes with one of the following kits:

279818 (white)

W10186596 (midnight grey)

Contact your local dealer.

Failure to follow these instructions can result in death, fire, electrical shock, or serious injury.

ABC

A. Standard rear offset exhaust installation B. Left or right side exhaust installation

C. Bottom exhaust installation (not an option with pedestal installations)

Alternate installations for close clearances

Venting systems come in many varieties. Select the type best for your installation. Two close-clearance installations are shown. Refer to the manufacturer’s instructions.

AB

A.Over-the-top installation (also available with one offset elbow)

B.Periscope installation

NOTE: The following kits for close clearance alternate installations are available for purchase. To order, please see the “Assistance or Service” section.

Over-the-Top Installation: Part Number 4396028

Periscope Installation (For use with dryer vent to wall vent mismatch):

Part Number 4396037 - 0" (0 mm) to 18" (457.2 mm) mismatch

Special provisions for mobile home installations

The exhaust vent must be securely fastened to a noncombustible portion of the mobile home structure and must not terminate beneath the mobile home. Terminate the exhaust vent outside.

Determine vent path

Select the route that will provide the straightest and most direct path outdoors.

Plan the installation to use the fewest number of elbows and turns.

When using elbows or making turns, allow as much room as possible.

Bend vent gradually to avoid kinking.

Use the fewest 90° turns possible.

Determine vent length and elbows needed for best drying performance

Use the following Vent system chart to determine type of vent material and hood combinations acceptable to use.

NOTE: Do not use vent runs longer than those specified in the Vent system chart. Exhaust systems longer than those specified will:

Shorten the life of the dryer.

Reduce performance, resulting in longer drying times and increased energy usage.

The Vent system chart provides venting requirements that will help to achieve the best drying performance.

Vent system chart

NOTE: Side and bottom exhaust installations have a 90º turn inside the dryer. To determine maximum exhaust length, add one 90º turn to the chart.

Number of

Type of vent

Box or

Angled

90º turns

 

Louvered

hoods

or elbows

 

hoods

 

 

 

 

 

0

Rigid metal

64 ft (20 m)

58 ft (17.7 m)

 

 

 

 

1

Rigid metal

54 ft (16.5 m)

48 ft (14.6 m)

 

 

 

 

2

Rigid metal

44 ft (13.4 m)

38 ft (11.6 m)

 

 

 

 

3

Rigid metal

35 ft (10.7 m)

29 ft (8.8 m)

 

 

 

 

4

Rigid metal

27 ft (8.2 m)

21 ft (6.4 m)

 

 

 

 

10

Page 10
Image 10
Amana W10216187A manual Optional exhaust installations, Alternate installations for close clearances, Determine vent path