Before Use

Important!

Leave the unit in an upright position for at least 2 hours before use.

Always place the unit on an even surface.

The power cord has a built-in L.C.D.I. (Leakage, Current, Detection, Interruption) circuit breaker for added safety. If the power supply is interrupted, please press the reset button to reconnect the unit to the power source. The green light should be on.

Make sure the unit is connected to a correctly grounded power supply.

For proper operation, the unit must be vented to the outside.

Do not cover or obstruct the appliance inlet or outlet grilles.

To avoid the risk of shock, the product should never be used in bathrooms, shower rooms or in any other steamy or wet areas.

Always transport the unit in an upright position.

Do not sit or stand on the unit.

Do not place objects on the unit.

Do not touch the unit with wet/damp hands or when standing barefoot.

Drainage of the water container is required before moving the unit or putting it into storage.

If the electric socket is different from the plug provided, have a professionally qualified electrician replace the outlet with a suitable one. Avoid the use of adaptor plugs, multiple sockets and/or extension cords; if their use is necessary, ensure that they conform to the current safety regulations.

Do not pull the power cord or place it near a source of heat; always unroll it completely to avoid the possibility of dangerous overheating.

If the power cord is damaged, it must be replaced by a qualified person.

THE MANUFACTURER DISCLAIMS ANY RESPONSIBILITY IF THE ABOVE INSTRUCTIONS ARE NOT FOLLOWED.

Operation

Setting The Fan Speed

Press the SPEED button to choose the fan speed you require, high or low.

The indicator of high or low fan will light up at the same time.

If the unit is in AUTO mode, it will select the fan speed automatically according to the ambient temperature (the related indicators, cool, fan or heat will light up), at this time the fan speed switch is invalid.

Setting the Timer

Press the TIMER button to set the operating hours you desire (1 to 12 hours, the timer indicator will light up). When the set time has elapsed, the machine will turn off automatically. The display window will show the hour(s) you set as you press the TIMER button. If the timer button is not pressed, the unit will work continuously.

By pressing the timer button but without turning on the unit, you can PRE-SET the time for the machine to work. For example, if you press the timer to ‘2’,

the unit will come on automatically after 2 hours.

All the above functions can also be performed with the supplied remote control. This remote control requires 2 AAA batteries to operate.

Regulating the Airflow Direction

Turn the roller on the

Move the air vent

air vent to control

directly to adjust the

the airflow direction from

airflow direction

the vertical louvers.

from the horizontal

 

louvers.

IMPORTANT!

The compressor will start approximately 3 minutes after the unit is turned on (this will help prolong the life of the compressor). After switching the unit off, please wait at least 3 minutes before turning the unit back on.

The cooling system will switch off if the room temperature is lower than set. The fan, however, keeps working at the set level. If the ambient temperature rises above the chosen temperature +/-5°F,

the cooling will resume.

In heating mode, the compressor will switch off if the room temperature is HIGHER than the one set (the fan keeps working at the set level). When the room temperature drops 5°F below the chosen temperature, heating will resume.

This machine is equipped with an ANTI-FROST function. Sometimes, while using the heating function during low temperatures, the heating will stop for a while to melt the internal frost. When this occurs, wait for heating to resume.

As you switch on the heating, the fan will stop for 15-20 seconds prior to the unit starting.

4

9

Page 6
Image 6
Amcor 000E AL-10 owner manual Before Use, Setting The Fan Speed, Setting the Timer, Regulating the Airflow Direction

000E AL-10 specifications

Amcor 000E AL-10: Cutting-Edge Packaging Solution

Amcor 000E AL-10 is a state-of-the-art packaging innovation that leverages advanced technologies to provide producers with a high-performance solution designed for various packaging needs. This product is specifically engineered to deliver robust protection, enhanced shelf life, and improved product presentation. It is particularly popular in industries ranging from food and beverage to pharmaceuticals.

One of the main features of Amcor 000E AL-10 is its multilayer construction, which combines the best attributes of different materials. The layers typically include a combination of aluminum foil, polymer layers, and other barrier materials. This construction ensures an exceptional barrier against oxygen, moisture, and light, which are critical factors in preserving the quality and integrity of products.

In terms of technologies employed, Amcor 000E AL-10 utilizes a unique extrusion process that allows for uniform thickness across the packaging material. This uniformity not only enhances the mechanical properties of the package but also simplifies the manufacturing process. The associated quality control measures ensure that every batch meets stringent performance standards.

This packaging solution is designed with user convenience in mind. Its lightweight nature reduces shipping costs, while its durability ensures that products remain protected during transit and storage. Additionally, Amcor 000E AL-10 can be easily printed on, allowing brands to highlight their products with high-quality graphics and necessary regulatory information.

The characteristics of Amcor 000E AL-10 include its flexibility and ability to conform to various shapes and sizes, making it suitable for different product types. It can be heat-sealed to provide tamper-evident packaging, reinforcing the safety aspect of the products it encases. Moreover, Amcor has focused on sustainability with this packaging solution, ensuring that materials used in the production of the 000E AL-10 can be recycled or have reduced environmental impact.

Overall, Amcor 000E AL-10 is a versatile and technically advanced packaging solution that meets the demands of modern consumers and manufacturers alike. Its blend of protection, convenience, and sustainability makes it an ideal choice for businesses looking to enhance their product offerings while maintaining a competitive edge in the market.