Amcor AD 400E Table of Contents, Troubleshooting, Amcor Inc, Capacity moisture removal low, Cause

Models: AD 400E

1 6
Download 6 pages 17.28 Kb
Page 2
Image 2
Table of Contents

Table of Contents

Troubleshooting

Never try to repair or dismantle the dehumidifer yourself. Tampering with the unit may result in the loss of warranty and can endanger the user and property.

THANK YOU

.........1

Important Safeguards

1

SPECIFICATIONS

2

PARTS

3

SPECIAL FEATURES

4

Automatic Dehumidification

4

Continuous Drainage

4

Air Filter

4

OPERATION

.........5

Control Panel

5

Operation Instruction

5

Humidity Setting

5

Alarm Indicator

5

Defrost

5

Installing the Drainage Hose

6

Maintaining Set Humidity Level

6

MAINTENANCE

....7

How to Take Out the Filter

7

Problem

The Unit

Does Not Operate

Dehumidifying

Capacity (moisture

removal) low

Relative Humidity setting not reached after long period of operation

Cause
Solution

No power supply.

Plug power cord firmly into outlet.

Unit is not turned on.

Turn the unit on.

Humidity is set lower

Set humidity higher.

than room humidity.

 

Air filter is dirty and/or

Clean the filter.

blocked.

 

Ambient room temperature

Increase the room temperature.

too low.

 

Poor airflow circulation/

Improve the airflow.

obstruction.

 

Humidity is set lower

Set humidity higher.

than room humidity.

 

There are windows or

Check that the doors and windows

doors opened.

are closed.

Area/room is too large for

 

the capacity of the dehumidifier

 

Cleaning the Filter

..........................................7

End of Season Storage

....................................7

TROUBLESHOOTING

9

WARRANTY

......10

Alarm

Indicator On

Defrost Light On

The condensation discharge hose is not positioned correctly or is bent

Check if temperature is above 41 ° .

Air filter is dirty.

Air inlet/outlet grills are obsructed.

Check the hose is correctly positioned. Disconect and reconnect the appliance.

If temperature is not above 41 ° F and light still on, stop unit. Temperature is too low.

Clean Air Filter.

Clear Air Inlet/Outlet grills.

If you have any questions regarding the operation of the AD 400 E please contact AMCOR at 1-866-361-2233

If this product is defective or not working properly,

please DO NOT return to your retail store. Please contact Amcor for service or technical assistance

Amcor Inc.

www.amcorgroupusa.com

9

Page 2
Image 2
Amcor AD 400E Table of Contents, Troubleshooting, Amcor Inc, Problem The Unit Does Not Operate Dehumidifying, Cause