A Word to AM-80 Air Purifier Owners
This manual has been prepared to acquaint you with the proper installation, operation and maintenance of your
Please do not attempt to open, repair and/or clean any of the internal parts of the
We would like to take this opportunity to thank you for choosing an Amcor product, and to assure you of our continuing interest in your comfort, pleasure and health.
Safety
•The
•Do not clean the
•Do not insert any object into the openings of the
•Disconnect the product from the electrical outlet before cleaning the unit or any of its components.
•Do not connect the
•A slight sensation may be felt if the carbon filament ionizing element
(the carbon cord on the front air outlet) is touched.This is normal and presents no danger.This sensation may also be felt if you touch a person or a large metal object while your other hand is on the unit.
•WHEN NOT IN USE STORE OUT OF REACH OF CHILDREN!
Do not operate this unit if an oxygen tent or similar concentrated oxygen generating device is present in the room, or in a work area with bottled gases. However, the unit is safe to operate near a
Warning
•Any service, other than regular cleaning, filter replacement or scent clip replacement, should be performed by an authorized service representative.
Failure to do so could result in loss of warranty.
•To reduce the risk of electric shock, this equipment has a polarized plug
(one blade is wider than the other). This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact qualified personnel to install the proper outlet.
Do not alter the plug in any way.
•If the supply cord becomes damaged, it must be replaced by the manufacturer or its service agent or similarly qualified person in order to avoid a hazard.
Replacing the HEPA Filter Unit
It is recommended to replace the HEPA filter approximately once a year or earlier, depending on the accumulated dirt. See “Filter Condition Indicator” chart (fig. 7).
When it is time to change the filter, follow the steps below:
1.Purchase a new HEPA filter by sending the enclosed mail order form.
(The replacement filter assembly contains both a new
2.Face the air intake grill.
3.Press and release the filter cover (fig. 2).
4.Remove the entire HEPA filter (fig. 6).
(Dispose of this entire assembly including the old
5.Install the new HEPA filter by inserting bottom edge first and align into place.
6.Replace the filter cover, bottom edge first, and snap into place (fig. 5).
Technical Data
Power Rating: 120V/60HZ
Power Switch | Air Flow | Power Consumption |
Position | Rate (cfm) | (watts) |
High | 64 | 45 |
Low | 40 | 30 |
Nominal Ionization Voltage: -5.5 KV
Total negative ions output: 2.5 x 10 12 = 2.5 trillion negative ions per second. Direct contact with the carbon ionizing filament is completely safe.
Safety:
The
Ozone:
The ozone level is two times lower than permissible by UL safety standards.
2 | 7 |