Amcor AOM 243HX, AWM 093HX, AOM 183HX installation manual Failure code, Fault code

Models: AOM 243HX AWM 093HX AOM 183HX

1 28
Download 28 pages 28.74 Kb
Page 22
Image 22
Failure

Failure

Failure code

 

 

Communication failure

F1

 

 

Failure of room temperature sensor.

F2

 

 

Failure of tube-exit temperature sensor

F3

 

 

Failure of tube-entry temperature sensor

F3

 

 

Failure of tube-midpoint temperature sensor

F3

 

 

Failure of PG fan

F4

 

 

Fault

Fault code

 

 

Fault of outdoor unit transducer module

P2

protecting.

 

 

 

Outdoor unit AC input too big.

P3

 

 

Outdoor unit compressor exhaust temperature

 

too high, outdoor environment temperature

P4

ultra warm , compressor outer cover temperature

 

switch disconnection .

 

The outdoor machine direct current bus bar

P7

is unusual in voltage.

 

 

 

Fault of lack refrigerant or fault of reversing

P8

valve.

 

Fault of the outdoor temperature sensor.

F6

 

 

Fault of outdoor unit drive, fault of compressor

FC

start.

 

 

 

Page 22
Image 22
Amcor AOM 243HX, AWM 093HX, AOM 183HX installation manual Failure code, Fault code