Amcor CPLMB 14000E Specifications, Emptying the Internal Water Container, Model Number, Remarks

Models: CPLMB 14000E

1 8
Download 8 pages 32.61 Kb
Page 4
Image 4
Specifications

Specifications

Model Number

CPLMB 14000E

 

 

Cooling Capacity

14,000 BTU/hr

 

 

Power Consumption

1,100 W / 9.8 A

 

 

Humidity Removal Capacity

80 pints / Day

 

 

Recommended room size

Up to 400 sq. ft.

 

 

Power Supply

115V / 60Hz / 1 Phase

 

 

Compressor

Rotary

 

 

Refrigerant

R-22

 

 

Fan Speed

3 (2 + 1 Turbo)

 

 

Temperature Set Range

64°F - 90°F

 

 

Timer

0-24 hours

 

 

Weight

75 lbs.

 

 

Dimensions

20"W x 16"D x 33"H

 

 

REMARKS:

The cooling capacity of the unit may be affected by the height of the ceiling, quality of insulation, number of windows, etc.

Emptying the Internal Water Container

NOTE: A proper balance between temperature and humidity is critical to maintain a comfortable living environment. If humidity is high, it will be necessary to empty the Internal water container frequently, until the ideal humidity is reached.

When the internal water container is full, the back light on the LCD display flashes. The unit will shut off automatically, beep 15 times and must be drained before it will restart.

To Drain the Unit:

Switch off the unit and remove the plug from the wall socket.

DO NOT MOVE THE UNIT. Doing this can result in water leakage, damaging your floor or carpet.

Place the drain pan on the floor under the drain cap.

Remove the drain cap and the rubber stopper from the drain, and let the water run out. Partially fill the drain pan, replace the rubber stopper, and empty the drain pan. This procedure must be repeated until the unit is empty.

Replace the rubber stopper and drain cap.

Put plug into the wall socket, and switch the unit on. The warning signal should be off.

For Continuous Drainage:

Switch off the unit and remove the plug from the electrical outlet.

Remove the Drain Cap and Rubber Stopper. Drain if necessary.

Connect a Drain Tube (not included) (20mm / 3/4" inner dimension) on to the water outlet.

Place the other end in a drain. Make sure the tube is free from twists and bends. The tube must decline over its entire length.

NOTE: When restarting the unit it may take up to 3 minutes for the compressor to turn on.