Architect & Engineer Specification

AMERICAN DYNAMICS

 

 

VIDEOEDGETM NETWORK VIDEO RECORDER

optical drive. The bays must be behind a locking front cover that restricts access not only to the drives, but also to the power switch and reset switch.

83.The Network Video Recorder shall be the American Dynamics VideoEdge® Series or equivalent.

2.03BUNDLED SERVER MECHANICAL SPECIFICATIONS

Unit Dimensions (HxWxD)

8.64 cm

(3.4”)

High with Bezel

 

44.43 cm

(17.5”)

Wide

 

74.40 cm

(29.31”)

Deep

Rack Height

Two units (2U)

Rack-mountable

 

 

chassis

 

Unit Weight

23 kg.

(50.71 lbs.) Maximum

 

 

 

configuration

2.04BUNDLED SERVER ELECTRICAL POWER REQUIREMENTS

Input

Redundant 750W Hot-Plug Auto-Switching

 

100-220 VAC, 50/60 Hz

2.05BUNDLED SERVER ENVIRONMENTAL CONDITIONS

Operating Temperature

10° to 35° C (50° to 95° F)

 

Storage Temperature

-40° to 65° C (-40° to 149° F)

 

Operating Relative Humidity

20% to 80% non-condensing (twmax=29C)

Storage Relative Humidity

5% to 95% non-condensing (twmax=38C)

Operating Vibration

0.26G at 5Hz to 350Hz for 2 minutes

 

Storage Vibration

1.54Grms Random Vibration at 10Hz to 250Hz

 

 

for 15 minutes

 

Operating Shock

1 shock pulse of 41G for up to 2ms

 

Storage Shock

6 shock pulses of 71G for up to 2ms

 

Operating Altitude

-16m to 3,048m (-50ft to 10,000 ft)

 

Storage Altitude

-16m to 10,600m (-50ft to 35,000 ft)

 

Emissions

FCC (U.S. only) Class B

 

 

 

ICES (Canada) Class B

 

 

 

CE Mark (EN 55022 Class B, EN55024,

 

 

EN61000-3-2, EN61000-3-3)

 

 

 

VCCI (Japan) Class B

 

 

 

BSMI (Taiwan) Class A

 

 

 

C-Tick (Australia/New Zealand) Class B

 

8200-2608-01 B0

VideoEdge® Network Video Recorder

18 of 20

Page 18
Image 18
American Dynamics ADNSNVR-CL1 Bundled Server Mechanical Specifications, Bundled Server Electrical Power Requirements