Installation

Electrical Specifications

 

Utility Power

Cable

 

 

 

Input

 

 

 

 

 

Connection

Three Position

Cable Adapter (5/8-24)

Terminal Block

Terminal Block to Coax Center Conductor

 

 

 

 

Nominal Voltage

220 V

63 V

 

 

 

Allowable Input range

165-270 V

40-75 V

 

 

 

Maximum Current

15 A

18 A

 

 

 

Input Current Limiting

10 A

N/A

 

 

 

Output

 

 

 

 

 

Connection

Three Position

Cable Adapter (5/8-24)

Terminal Block

Terminal Block to Coax Center Conductor I

 

 

 

 

Allowable Output range

 

40-75 V

 

 

 

Initial Connection Delay

 

Primary - None

 

Secondary - 5.5 seconds

 

 

 

 

 

Time to connect attached FRP

N/A

350 mS maximum

to cable system after output

 

 

failure

 

 

 

 

 

Physical Specifications

Characteristic

Specification

 

 

Height/Width/Depth

15” x 7” x 8” (38.1 x 17.8 x 20.3 cm)

 

 

Weight

14 lbs (6.4 kg)

 

 

Installation

Unpack

Read the Safety Guide before installing this unit. The User Manual and Safety Guide are accessible on the APC Web site, www.apc.com.

Inspect the unit upon receipt. Notify the carrier and dealer if there is damage. The packaging is recyclable; save it for reuse or dispose of it properly. Check the package contents:

4

Broadband Automatic Disconnect Switch User Manual

Page 4
Image 4