4
CTFLP Enclosure Installation
Loosen (do not remove), the four .25” (.63 cm) nuts on the bracket assembly.
Wall Mount Units: Select fasteners that will accommodate the weight of the unit including the
power supply.
Wiring
1. Attach conduit to the 1/2 “ hole on the bottom of the unit and wire the input line.
INDEX ITEM DESCRIPTION
1 60/90 VAC Indicator Lamp Lamp is on when normal output is present
2 Output Cable Adapter Coax adapter for power supply output
3 Conduit entry point Physical entry point for conduit
4 Ground Wire Lug Provides connection of chassis to earth ground
5 Pole Bracket Bracket for mounting the enclosure on a pole or wall
Mounting Bracket is permanently
attached to enclosure.
.62” (1.6 cm) Pole Bolt
and Square Washer
Bottom Edge of
Enclosure

Bottom View