AWAY

OVER

25% 50% 75% 100% LOAD

INVERTER LOAD

AWAY

TEST

Mode MUTE HOME

INVERTER

ON

ON

DISABLE

MAINS BATTERY FAULT

Figure 4. Home UPS Front Panel Controls and Indicators

Table 1. Home UPS Indicators

Mode

ON LINE

ON LINE SELF TEST

ON BATTERY SELF TEST

ON BATTERY

BATTERY DISCONNECTED

Short Circuit (heavy overload)

ON BATTERY Low Battery Warning

On

Mains

(green)

On

Flashing Flashing

Off

On

Off

Off

On

Battery (yellow)

Off

Off

On

On

Off

Off

On

Fault (red)

Off

Off

Off

Off

Flashing

On

Off

INV

Disable

(red)

Off

Off

Off

Off

Off

Off

Off

Buzzer

Off

Off

Off

Chirp every 2 seconds

Continuously On

Constant Beeping, Can be muted through front panel TEST/MUTE push button.

Description

The unit is ON-LINE.

The unit is in ON-LINE Self-Test mode.

The unit is in ON-BATTERY Self-Test mode, and the load is less than 25%.

The unit is in ON-BATTERY mode, and the load is less than 25%.

The unit is ON-LINE mode; battery is disconnected.

The unit is in FAULT state, due to short circuit fault.

Power Meter

Power Meter

Power Meter

Power Meter

25%

on

on

on

on

50%

off

on

on

on

Table 2. Load Indications

75%

100%

Overload

off

off

off

off

off

off

on

off

off

on

on

off

 

 

 

Buzzer

off

off

off

off

Description

The unit is in ON-BATTERY mode, and the load is less than 25%.

The unit is in ON-BATTERY mode, and the load is between 25% and 50%.

The unit is in ON-BATTERY mode, and the load is between 50% and 75%.

The unit is in ON BATTERY mode; the load is between 75% and the overload limit.

NOTE: In the case of a sustained overload, the Home UPS will be turned off automatically after one minute, and will wait in the fault state for a minute. After that, it will restart again. If the overload still persists, the Home UPS will be turned off again after one minute, and will wait in fault state for one minute and restart again. In the same way, it will try for three restarts. If the overload still persists, it will stay in fault state permanently until the unit is restarted with push button. If the time interval between two consecutive overloads is more than 5 minutes, then the latest overload is considered as a fresh overload and three restart cycle will begin again.