American Standard dimensions 3351.128/3352.128, 3353.128/3354.128, Revised 11/08, Barrier Free

Models: 3354.128 3352.128 3351.128 3353.128 047007-0070A

1 2
Download 2 pages 9.13 Kb
Page 2
Image 2
3351.128/3352.128

AFWALL™ FloWise® ELONGATED 1.28 GPF FLUSHOMETER TOILET

3353.128/3354.128NOTES: BARRIER FREE

3351.128/3352.128

19mm

(3/4)

FINISHED WALL

660mm

(26)

NOT RECOMMENDED). 73mm (2-7/8)

470mm

(18-1/2)

C/L OF SEAT POST HOLES 140 mm (5-1/2) CENTER

1" N.P.T. OR C.W.T. SUPPLY AS REQUIRED TO FLUSH VALVE

C/L

121mm Manual backgroundManual background (4-3/4)

 

 

 

356mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(14)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

292mm

1-1/2 SPUD

(4) 22mm

(11-1/2)

 

 

 

(7/8)

 

 

 

 

HOLES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

95mm (3-3/4)

70mm (2-3/4)

133mm (5-1/4)

330mm

 

229mm

 

(13)

381mm

(9)

191mm

 

 

(7-1/2)

 

(15)

 

 

 

 

FINISHED

 

 

133mm

FLOOR

 

C/L OF

 

(5-1/4)

 

 

OUTLET

 

 

 

32mm (1-1/4)

3353.128/3354.128

(3/4)

19mm

95mm (3-3/4) Manual backgroundManual background

70mm (2-3/4) 133mm (5-1/4)

Manual backgroundFINISHED WALL

660mm

(26)

76mm(3) DIA. HOLE IN WALL

 

FOR 1-1/2 SPUD

C/L

 

470mm

 

 

(18-1/2)

 

356mm

 

 

 

 

(14)

C/L OF SEAT POST HOLES

 

140mm(5-1/2) CENTERS

89mm

 

 

 

 

(3-1/2)

 

330mm

 

229mm

(13)

(4) 22mm (7/8)

(9)

 

 

DIA. HOLES

 

 

381mm

 

FINISHED

(15)

 

 

 

FLOOR

C/L OF

 

 

OUTLET

 

32mm

 

 

(1-1/4)

 

 

191mm

(7-1/2)

133mm

(5-1/4)

330mm

283mm (13) (11-1/8)

NOTES:

Toilet designed to meet ADA accessibility standards when top of seat height set at 432 to 483mm (17" to 19") from finished floor.

PRODUCT 3351.128 AND 3353.128 SHOWN, 3352.128 AND 3354.128 SAME AS EXCEPT

WITH SLOTTED RIM FOR BED PAN HOLDING.

WASTE OUTLET SEAL RING MUST BE NEOPRENE OR GRAPHITE-FELT (WAX RING

NOT RECOMMENDED).

SUGGESTED 2mm (1/16) CLEARANCE BETWEEN FACE OF WALL AND BACK OF BOWL.

TO COMPLY WITH AREA CODE GOVERNING THE HEIGHT OF VACUUM BREAKER ON

THE FLUSHOMETER VALVE, THE PLUMBER MUST VERIFY DIMENSIONS SHOWN FOR

SUPPLY ROUGHING.

FLUSHOMETER VALVE NOT INCLUDED WITH FIXTURE AND MUST BE

ORDERED SEPARATELY.

CARRIER FITTING AS REQUIRED TO BE FURNISHED BY OTHERS.

PROVIDE SUITABLE REINFORCEMENT FOR ALL WALL SUPPORT.

IMPORTANT: Dimensions of fixtures are nominal and may vary within the range of tolerances established by ANSI Standard A112.19.2.

These measurements are subject to change or cancellation. No responsibility is assumed for use of superseded or voided pages

 

M70

 

© 2008 AS America Inc.

Revised 11/08

 

Page 2
Image 2
American Standard 047007-0070A 3351.128/3352.128, 3353.128/3354.128, Revised 11/08, Barrier Free, Not Recommended