TM
AMARILIS™
P e r s o n a l S h o w e r S y s t e m
Installation Instructions for: DELUXE SHOWERHEAD | 1660.100 SERIES |
BODY SIDE SPRAY | 1660.120 SERIES |
ROUGHING-IN DIMENSIONS
DELUXE SHOWERHEAD |
FINISHED WALL
OPTIONAL TO
FINISHED FLOOR
USUALLY 65" TO 78".
FOR USE WITH BODY
SIDE SPRAYS 72" TO 78"
IS RECOMMENDED.
1/2"
MAX.
BODY SIDE SPRAY
SEE
RECOMMENDED
INSTALLATION
BELOW
FINISHED
WALL
1/2"
MAX.
RECOMMENDED INSTALLATION FOR MULTIPLE BODY SIDE SPRAYS:
Each installed BODY SIDE SPRAY requires 2.5 GPM for an adequate spray flow.
For maximum flow, use Amarilis
Connect multiple body side sprays to spout outlet of valve.
1/2" S.P.S. | 16" |
24" |
|
| 16" |
32" OPTIONAL |
|
TO FINISHED | 28" OPTIONAL |
FLOOR | TO FINISHED |
| FLOOR |
- 2 SPRAY | - 3 SPRAY |
TO SHOWERHEAD
3 HANDLE |
|
B/S VALVE |
|
| 4" |
| |
DIVERTER |
|
VALVE | TUB SPOUT |
|
Provide
Connect deluxe showerhead to shower outlet of valve.
1ROUGHING-IN
Prepare shower connection nipples per
Cap nipples, turn on water supplies and check for leaks.
2SHOWERHEAD INSTALLATION
Slide ESCUTCHEON forward and compress BELLOWS to expose supply connectors.
Use adjustable wrench to install SHOWERHEAD.
Turn on water supplies and check for leaks.
Push ESCUTCHEON back until seated flush against wall.
SUPPLY COUPLING
CONNECTOR NUT
FLOW
ESCUTCHEON REGULATOR AND
BELLOWS
3SERVICE
To increase swivel tension:
Compress BELLOWS towards rear to expose ball joint. Wrench tighten COUPLING NUT to increase tension.
The FLOW REGULATOR may accumulate debris causing reduced water flow. To clean, remove SHOWERHEAD, then:
Remove ESCUTCHEON and BELLOWS.
Unscrew SUPPLY CONNECTOR to remove FLOW REGULATOR.
Clean FLOW REGULATOR,
SHOWERHEAD.
P r i n t e d i n W e s t G e r m a n y | A l l p r o d u c t | n a m e s l i s t e d | h e r e i n a r e t r a d e m a r k s o f A m e r i c a n S t a n d a r d I n c . |