2 CONNECT SUPPLIES
Carefully bend copper supplies to meet water supply lines using the palms of the hands to avoid kinking.
Connect HOT water supply line to LEFT tube, and COLD water supply line to RIGHT tube using appropriate connectors.
OR
3 INSTALL POP-UP DRAIN
FLANGE
Push DRAIN BODY down into trap. |
| |
Thread LOCKNUT, WASHER and GASKET onto | SINK | |
DRAIN BODY. | ||
|
STOPPER
FLANGE
GASKET
Remove one end of CLIP from PIVOT ROD by squeezing ends together while sliding.
Insert PIVOT ROD into second or third hole in EXTENSION and reassemble CLIP. (EXTENSION may need to be bent.)
Adjust STOPPER height by repositioning EXTENSION and tightening THUMBSCREW.
Feed DRAIN BODY up through SINK. Place FLANGE GASKET over BODY and thread FLANGE FULLY onto BODY.
Tighten LOCKNUT firmly, keeping the PIVOT ROD pointed towards the back of the SINK.
Drop STOPPER into DRAIN BODY. | LOCKNUT |
|
Position EXTENSION ROD onto
DRAIN
BODY
GASKET
WASHER
CLIP
PIVOT
ROD
TRAP
THUMBSCREW
EXTENSION
ROD
DRAIN BODY
TRAP
EXTENSION
ROD
CLIP
PIVOT
ROD
4 TEST INSTALLED FAUCET
Move handle down into "off" position and remove AERATOR.
For
Turn on water supplies and check connections for leaks.
Operate handle up and down, left and right to flush water lines thoroughly.
Move handle down to "off" position and replace AERATOR or FLOW DEVICE.
5 HOT LIMIT STOP
By restricting handle rotation and limiting the amount of hot water allowed to mix with the cold, the HOT LIMIT SAFETY STOP reduces risk of accidental scalding. To set the maximum hot water temperature of your RELIANT faucets, all you need to do is adjust the setting on the HOT LIMIT SAFETY STOP.
Remove HANDLE, CAP and HOT LIMIT STOP. Follow "A" or "B" to adjust maximum discharge temperature.
"A"
PRY UPWARD TO UNLOCK
AND ROTATE COUNTER- CLOCKWISE ONE CLICK
FRONT
ADJUSTMENT WHEN WATER IS TOO HOT
"B"
PRY UPWARD TO UNLOCK AND ROTATE CLOCKWISE
FRONT
ADJUSTMENT WHEN
WATER IS TOO COLD
6 SERVICE
AERATOR may accumulate dirt causing distorted and reduced water flow. Remove AERATOR. Clean AERATOR and FLOW RESTRICTOR. Replace AERATOR.
If faucet drips, operate handle several times from "off" to "on". Do not apply excessive force.
Clogged CARTRIDGE inlets may cause reduced flow in "full on" hot or cold. To clean inlets, first turn off water supply, then:
Remove HANDLE, CAP, HOT LIMIT STOP and CARTRIDGE. Clean inlets and MANIFOLD.
Reassemble CARTRIDGE, alternately tightening screws. Replace HOT LIMIT STOP , CAP and HANDLE. Check flow.
HANDLE | CARTRIDGE |
SET SCREW | SEALS |
| |
HANDLE |
|
BUSHING |
|
CAP | |
| |
HOT LIMIT | ROD |
| |
STOP |
|
CARTRIDGE |
|
SCREWS |
|
CAP |
|
RETAINER | AERATOR |
| |
| HOTLINE FOR HELP |
| For |
| 1 (800) |
| Weekdays 8:00 a.m. to 4:00 p.m. Eastern Time |