![INSTALLATION AND FRAMING INSTRUCTIONS](/images/new-backgrounds/91896/9189613x1.webp)
INSTALLATION AND FRAMING INSTRUCTIONS
The variety of installations possible for this air bath may require framing procedures other than those shown. Locate studs as needed. Ensure
1.Position the air bath into the installation opening and level the deck in both directions, shimming the integral support feet IF necessary. Mark the final position of the underside of the deck by tracing a line on to the studs (see Figure 1).
2.Remove the air bath and attach a 1 x 4 stringer to the studs, with the top of the stringer touching the traced line.
!The rim of the bath must not support weight.
. Install drain components to the air bath following the drain installation instructions. Before replacing your air bath for final installation, be certain that an opening has been provided in the
The floor structure beneath the bath must be able to support a total weight of bath, water, and
!bather. Refer to Table 1 under total weight for your model.
For Models: 2425V.168C-RHO and 2425V.268C-LHO;
This bath must be supported along its entire bottom. Use mortar as bedding material (do not use sand or foam). Apply enough mortar to support the complete bottom of the bath. After the mortar has been poured, and before it sets, position bath within recess until the rim is leveled against the leveling stringers (see "Typical Recess Installation") shown below.
!The rim of the bath must not support weight. Allow the mortar material to completely harden before applying weight to the rim or bottom of the bath. Any finish material such as tile or wall board must be
For Models: 2645V.068C, 2771V.068C, 7236V.068C and 2422V.068C;
Replace air bath and
!The rim of the bath must not support weight. If foundation base is used, allow the bedding material to completely harden before applying weight to the rim or bottom of the bath. Any finish material such as tile or wall board must be
FIGURE 1
TYPICAL INSTALLATION
C
| TILE | |
| WALLBOARD | |
TILE | SEALANT | |
BATH | ||
BEAD | ||
| ||
STRIP |
| |
| ADHESIVE | |
| LEVELING STRINGER | |
| 1 x 4 (not for support) |
NOTE: Tile bead kit not included and must be purchased separately.
TYPICAL RECESS INSTALLATION
TYPICAL PIER TYPE INSTALLATION
AS DESIRED
F
CUTOUT
C
G
CUTOUT
C
E
NOTE:
FRONT EDGE
OF BATH MUST
BE SUPPORTED BY STUD WALL OR AMERICAN STANDARD APRON KIT
D | 12 |
| |
W | (05 mm) |
LEVELING
STRINGERS24 (10 mm)
ACCESS PANEL MUST BE LOCATED ON THE SAME SIDE AS THE AIR BATH.
ALLOW OPEN FRAMING ON BLOWER/MOTOR END FOR SERVICE.
ACCESS PANELS NOT REQUIRED
FOR BATH TUBS.
AS DESIRED
MOUNTING
SURFACE
WATERPROOF SEALANT
BATH
12
(05 mm)
24
(10 mm)
ACCESS PANEL MUST BE LOCATED ON THE SAME SIDE AS THE AIR BATH.
ALLOW OPEN FRAMING ON BLOWER/MOTOR END FOR SERVICE.
ACCESS PANELS NOT REQUIRED
UNLESS AN ACCESS OPENING OF AT LEAST 12" X 24" (305 X 610mm)
IS PROVIDED, WARRANTY SERVICE WILL NOT BE PERFORMED. (EXCEPT 2425 WHERE APRON IS PRIMARY ACCESS OPENING)
FOR E & D DIMENSIONS SEE TABLE 1 ON PAGE 5.
FOR BATH TUBS.
UNLESS AN ACCESS OPENING OF AT LEAST 12" X 24" (305 X 610mm)
IS PROVIDED, WARRANTY SERVICE WILL NOT BE PERFORMED.