American Standard 2742.328.K2 dimensions TOWN SQUARE 6 x PREMIUM AIR BATH, High Gloss, Rev. 2/08

Models: 2742.328 2742.328.K2

1 2
Download 2 pages 12.09 Kb
Page 2
Image 2
GENERAL SPECIFICATIONS FOR 2742

TOWN SQUARE® 6' x 42"

PREMIUM AIR BATH

HIGH GLOSS

4"

 

 

71-1/2"

 

 

35-3/4"

(1816mm)

INTEGRAL

CONTROL

(102mm)

 

 

FITTING DECK

PANEL

 

(908mm)

 

 

13-1/4"

 

 

2-1/4" X 14"

 

 

 

 

 

(337mm)

 

 

 

(57 X 356mm)

 

 

 

 

 

 

3"

 

 

 

 

 

(76mm)

C/L OF

 

 

10-1/4”

 

EDGE OF

26-3/4

 

 

FLOOR

DRAIN

 

(260mm)

 

CUTOUT

OUTLET

(679mm)

 

FLOOR CUTOUT

 

 

 

 

 

41-3/4"

 

 

9" X 19"

 

 

 

 

(229 X 459mm)

 

(1060mm)

7-3/4” TYPICAL

AIR BLOWER

 

 

3/4"

(197mm)

 

 

 

 

 

 

 

 

 

(19mm)

 

 

 

 

 

OUTLINE OF SKID

 

20 AIR JETS

PROVIDE ACCESS

RESISTANT SURFACE

OUTLINE OF CUTOUT

TO BLOWER FOR

 

 

70" X 40-1/4" (1778 X 1022mm)

SERVICE ON ALL

 

 

 

 

INSTALLATIONS

2"

AIR BLOWER

LEVELING STRINGER

C/L OF

(51mm)

(NOT FOR SUPPORT)

OVERFLOW

 

 

 

 

3-1/4"

22"

 

 

 

 

(559mm)

 

 

 

 

(83mm)

20"

 

 

 

 

ROUGH

 

 

 

 

(508mm)

 

 

 

 

FLOOR

 

 

 

 

 

INTEGRAL FEET WITH

1-1/2" N.P.T. THREADS

 

ATTACHED BASEBOARD

 

1-1/2" O.D.TAILPIECE

 

 

5/8"

 

 

 

 

(16mm)

ELECTRICAL SPECIFICATIONS 3" (76mm)

GENERAL SPECIFICATIONS FOR 2742

AIR MASSAGE SYSTEM

INSTALLED SIZE

 

 

 

 

71-1/2 x 41-3/4 x 22 In. (1816 x 1060 x 559mm)

 

 

 

 

WEIGHT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

115 Lbs. (52 Kg.)

WEIGHT w/WATER

 

 

 

 

 

 

 

 

 

 

690 Lbs. (313 Kg.)

 

 

 

 

 

 

 

 

 

GAL. TO OVERFLOW

 

 

 

 

 

 

 

 

 

 

69 Gal. (261 L)

 

 

 

 

 

 

 

 

 

 

BATHING WELL AT SUMP

 

 

 

 

 

41 x 21-1/2 In. (1041 x 546mm)

BATHING WELL AT RIM

 

 

 

 

 

 

62 x 31-1/2 In. (1574 x 800mm)

WATER DEPTH TO OVERFLOW

 

 

 

 

 

14-1/4 In. (362mm)

FLOOR LOADING

 

 

 

 

 

 

 

33 Lbs./Sq.Ft. (163 Kgs./Sq.m)

(PROJECTED AREA)

 

 

 

 

 

 

 

 

 

 

 

 

 

PTS.

 

 

 

 

 

 

 

27.8

CUBE (FT3)

 

 

 

 

 

 

55.7

 

 

 

 

 

 

 

ELECTRICAL SPECIFICATIONS

BLOWER

 

1.0 HP, 10 AMPS ,120V.

NOTES:

BATH CAN BE INSTALLED EITHER ABOVE OR BELOW FLOOR LINE AS PIER, ISLAND OR PENINSULA TYPE INSTALLATION. SUMP OF BATH IS SUPPORTED BY INTEGRAL FEET. NO ADDITIONAL SUPPORT REQUIRED. ENCLOSING MATERIALS BY OTHERS.

IF INSTALLING A DECK-MOUNTED FITTING, BEFORE DRILLING ANY HOLES: CHECK FOR INTERFERENCE WITH CIRCULATING SYSTEM PIPING AND DRAIN OVERFLOW. MOUNTING HOLES DRILLED BY INSTALLER.

REFER TO INSTALLATION INSTRUCTIONS SUPPLIED WITH BATH FOR ADDITIONAL INFORMATION. FITTINGS NOT INCLUDED AND MUST BE ORDERED SEPARATELY.

PROVIDE SUITABLE REINFORCEMENT FOR ALL SUPPORTS.

IMPORTANT: Dimensions of fixtures are nominal and may vary within the range of tolerances established by ANSI Standard Z124.1 / CSA Certified. These measurements are subject to change or cancellation. No responsibility is assumed for use of superseded or voided leaflet.

 

H24

 

© 2008 AS America Inc.

Rev. 2/08

 

Page 2
Image 2
American Standard 2742.328.K2 dimensions TOWN SQUARE 6 x PREMIUM AIR BATH, High Gloss, Rev. 2/08, Electrical Specifications