American Standard 2980, 2981 installation instructions Install Handles, Figure A, Service, 1 2

Models: 2981 2980

1 3
Download 3 pages 35.22 Kb
Page 2
Image 2
9

3 VALVE ASSEMBLY

Install LOCKNUTS (1) and RUBBER WASHERS (2) onto valve shanks.

Push TUBING (3) ends into VALVE (4) side outlets. Insert VALVES (4) into mounting holes from underside of ledge.

Press TEE (5) onto SPOUT SHANK (6) making certain that the O-RING (7) is properly seated on SHANK (6). Push COUPLING (8) into TEE (5) and attach to SPOUT SHANK (6) and tighten.

9

MOUNTING 11

SURFACE

10

Thread of VALVE BODY (4) should extend at least 5/16 inch above MOUNTING SURFACE (11). If necessary, adjust LOCKNUT (1).

Place RUBBER RING (10) into ESCUTCHEON ADAPTERS (9) and thread onto valves until snug against internal stop.

Tighten LOCKNUT (1) to secure VALVE (4) position.

Slide FERRULE (12) and COUPLING NUT (13) to outlet of VALVE (4) and tighten COUPLING NUT (13) firmly.

9 9 7

4 INSTALL HANDLES 10 Figure "A"

4

Connect HOT water supply to inlet of left VALVE and COLD water supply to inlet of right VALVE using appropriate connector.

9

10

12

6 7

13 6

5/16'' MIN.

4

 

 

HOT

 

11

MOUNTING

12

4

 

 

 

 

 

SURFACE

3

 

 

 

2

 

5

 

 

 

 

8

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

13

COLD

4 INSTALL HANDLES

Push ADAPTER (1) on VALVE STEM (2), so that the hole of the

ADAPTER (1) without spline is facing up. See figure "A".

Thread HANDLE BASE (3) onto DECK ADAPTER (7)

Push HANDLE (4) onto ADAPTER (1).

 

TOP

Find correct position of HANDLE (4) by adjusting male teeth on

 

ADAPTER (1) to female teeth in HANDLE (4).

 

 

Secure HANDLE (4) with HANDLE SCREW (5).

Figure "A"

 

 

 

Push INDEX CAP (6) in hole of HANDLE (4).

 

 

 

SPLINE END DOWN

2

 

 

6

5

4

3

1

7

5 SERVICE

To change direction of handle rotation, proceed as follows:

5 SERVICE Turn valve to OFF position.

1 Pull out INDEX CAP (1) and remove HANDLE SCREW (2).

Manual background Pull off HANDLE (3), and unscrew ESCUTCHEON (4).

Manual background Pull off STEM ADAPTER (7).

Manual background Remove SPRING CLIP (6).

Manual background Lift STOP WASHER (5), turn 90° and replace.

Manual background Replace SPRING CLIP (6) and STEM ADAPTER (7). Manual background Reinstall ESCUTCHEON (4) and HANDLE ASSEMBLY (1,2 & 3).

If spout drips, operate handles several times from OFF to ON position. Do not force - handles turn only 90° .

1

2

3

4

90°

7

 

 

5

6

M 9 6 8 2 1 2

Page 2
Image 2
American Standard 2980, 2981 installation instructions Install Handles, Figure A, Service, 1 2