American Standard 3461.128/3462.128/3465.128/3466.128, 3463.128/3464.128, Revised 12/08

Models: 3466.128 3464.128 3465.128 3461.128 3462.128

1 2
Download 2 pages 30.77 Kb
Page 2
Image 2
3461.128/3462.128/3465.128/3466.128

MADERA™ FloWise® 16-1/2" HEIGHT 1.28 GPF FLUSHOMETER TOILET

3463.128/3464.128NOTES: BARRIER FREE

3461.128/3462.128/3465.128/3466.128

FINISHED WALL

1" N.P.T. OR 1" C.W.T. SUPPLY TO FLUSH VALVEManual background

102mm

(4)

25mm

(1)

718mm (28-1/4)

470mm (18-1/2)

C/L OF SEAT POST HOLES 140mm (5-1/2) CENTERS

121mm

(4-3/4)711mm (28)

356mm (14)

1 - 1/2

SPUD

419mm (16-1/2)

13mm

(1/2)

 

338mm

 

FINISHED

 

 

FLOOR

(13-5/16)

 

Manual background150mm (5-7/8)

238mm Manual background (9-3/8)

Manual background 254mm Manual backgroundManual background

(10)C/L OF OUTLET

3463.128/3464.128

FINISHED WALL

718mm (28-1/4)

76mm

 

470mm

 

 

 

356mm

 

 

 

 

(3)

(18-1/2)

 

(14)

C/L OF SEAT POST HOLES 140mm (5-1/2) CENTERS

438mm (17-1/4)

419mm (16-1/2)

 

 

 

 

 

 

 

338mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FINISHED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(13-5/16)

 

 

 

 

 

 

 

 

 

 

 

 

 

150mm

 

FLOOR

 

 

238mm

 

 

 

 

 

 

 

 

(5-7/8)

 

 

 

 

 

 

 

 

13mm

 

 

 

(9-3/8)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(1/2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Manual background 254mm Manual backgroundManual background

(10)C/L OF OUTLET

 

NOTES:

 

PRODUCT 3451.160 AND 3453.160 SHOWN, 3452.160 AND 3455.160

 

SAME AS EXCEPT WITH SLOTTED RIM FOR BED PAN HOLDING.

 

TO COMPLY WITH AREA CODE GOVERNING THE HEIGHT OF VACUUM

 

BREAKER ON THE FLUSHOMETER VALVE, THE PLUMBER MUST

 

VERIFY DIMENSIONS SHOWN FOR SUPPLY ROUGHING.

 

THIS TOILET DESIGNED TO ROUGH-IN AT A MINIMUM DIMENSION

 

OF 254MM (10") AND A MAXIMUM DIMENSION OF 305MM (12") FROM

 

FINISHED WALL TO C/L OF OUTLET.

 

FLUSHOMETER VALVE NOT INCLUDED WITH FIXTURE AND MUST BE

 

ORDERED SEPARATELY. FLUSHOMETER VALVE REQUIREMENTS FOR

 

12" (305MM) ROUGH-IN: SWEAT EXTENSION NIPPLE IS REQUIRED.

 

REFER TO VALVE MANUFACTURER AND LOCAL CODES.

 

IMPORTANT: Dimensions of fixtures are nominal and may vary within

 

the range of tolerances established by ANSI Standard A112.19.2. These

 

measurements are subject to change or cancellation. No responsibility is

 

assumed for use of superseded or voided pages.

 

 

M62

 

© 2008 AS America Inc.

 

Revised 12/08

 

 

Page 2
Image 2
American Standard dimensions 3461.128/3462.128/3465.128/3466.128, 3463.128/3464.128, Revised 12/08, Barrier Free

FAQ

What are the dimensions of the MADERA FloWise toilet?

The dimensions of the MADERA FloWise toilet are specified in the manual for models 3461.128,3462.128,3465.128,3466.128.

Does the toilet come with a flushometer valve?

No, the flushometer valve is not included with the fixture and must be ordered separately. Refer to the manual for more information.

What are the rough-in requirements for the toilet installation?

The rough-in dimensions for the toilet installation are provided in the manual. Make sure to verify the dimensions for supply roughing to comply with area codes.