INSTALL HANDLES
CROSS HANDLE
Push ADAPTER (2) into HANDLE BASE (3) in a way that the male square on the ADAPTER (2) fits in the female 8 point star of the HANDLE (4).
Turn HANDLE STEM (1) to the off position. Push HANDLE BASE (3), ADAPTER (2) and HANDLE (4) onto VALVE STEM (1).
Tighten HANDLE SCREW (5).
Push INDEX CAP (6) in top of HANDLE (4).
LEVER HANDLE
Push ADAPTER (2) into LEVER HANDLE BASE (7) in a way that the male square on the
ADAPTER (2) fits in the female star of the HANDLE BASE (7).
Turn HANDLE STEM (1) to the off position. Push LEVER HANDLE BASE (7) and
ADAPTER (2) onto VALVE STEM (1).
Tighten HANDLE SCREW (6).
Check alignment, if not satisfactory aligned;
Push out ADAPTER (2) carefully.
Turn ADAPTER (2) either 45˚ or 90˚ so that male square on ADAPTER (2) catches different female square in LEVER HANDLE BASE (7).
Assemble and tighten HANDLE SCREW (6). Push INDEX CAP (8) in top of LEVER HANDLE BASE (7).
CROSS HANDLES | LEVER HANDLES |
6 6
5
4 4
5
3
2
1
8
6
7
2
MAKE WATER SUPPLY CONNECTIONS
NOTE: FLEXIBLE SUPPLIES OR
Connect water supply to FAUCET (1) with 1/2" IPS FLEXIBLE SUPPLIES (3) or 3/8"O.D.
tighten connections. Do not over tighten. Be careful not to kink copper supply when bending. Use tubing cutter to cut to proper length.
4
1
COUPLING NUT
FERRULE
3
. 3 & 7