SINK

1 INSTALL FAUCET

CAUTION

Turn off hot and cold water supplies before beginning.

Screw SPOUT onto BODY.

Place faucet in position on sink.

Assemble and tighten LOCKNUTS from underside of SINK.

Connect the HOT water supply to the left SHANK and the COLD water supply to the right SHANK using sealant, appropriate connectors, and COUPLING NUTS.

To install SPRAY:

Unscrew SPRAY CAP.

Place the HOLDER into the appropriate mounting hole. Assemble the SPRAY HOLDER WING NUT onto the shank of SPRAY HOLDER from below and tighten.

Feed SPRAY HOSE through HOLDER so SPRAY sits in HOLDER.

From underneath sink, attach COUPLING NUT of SPRAY HOSE to HOSE SHANK. Tighten COUPLING NUT firmly.

SINK

COLD

HOT

BODY COLDBODY SPRAY

SPRAY

PUTTYCAP

HOSE

SHANK

SPRAY

HOSE

SPRAY

HOLDER

WING

NUT

LOCKNUT

COUPLING

NUT

SPRAY HOSE

COUPLING NUT

2 TEST INSTALLED FAUCET

Remove AERATOR.

With handle in OFF position, turn on water supplies and check all connections for leaks.

Operate both handles to flush water lines thoroughly.

Operate SPRAY (if present).

Turn handles into OFF position and replace AERATOR.

3 SERVICE

STOP

WASHER

To change direction of handle rotation, proceed as follows:

PUTTYCAP Turn valve to OFF position.

SPRAY HOSE Pull out INDEX CAP and remove

HANDLE SCREW.

2 TEST INSTALLED FAUCET Pull off HANDLE BASE and remove

ADAPTER.

3 SERVICE Remove SPRING CLIP.

Manual background Lift STOP WASHER, turn 90° and replace.

Manual background Replace SPRING CLIP.

Manual background Reinstall HANDLE.

90°

SPRING

CLIP

Handle alignment.

Check alignment, if not satisfactory aligned;

Push out ADAPTER carefully.

Turn ADAPTER either 45˚ or 90˚ so that male square on ADAPTER catches different female square in HANDLE BASE.

Assemble and tighten

MOUNTING SCREW.

Push INDEX CAP in top of

HANDLE.

FEMALE SQUARE Manual background IN HANDLE BASE

HANDLE

ADAPTER

SQUARE

VALVE

STEM

AERATOR may accumulate dirt causing distorted and reduced water flow. Remove AERATOR and rinse clean.

If spout drips, operate handles several times from OFF to ON position. Do not force - handles turn only 90° .

P r o d u c t n a m e s l i s t e d h e r e i n a r e t r a d e m a r k s o f A m e r i c a n S t a n d a r d I n c . C A m e r i c a n S t a n d a r d I n c . 1 9 9 8

HOT LINE FOR HELP

For toll-free information and answers to your questions, call: