1

 

 

Turn off hot and cold water

 

CAUTION

 

supplies before beginning.

 

ROUGHING-IN FITTING

Prepare water supplies per "Roughing-in Dimensions."

Slip COUPLING NUT over supply pipe and screw UNION SWIVEL to pipe.

For Sweat Connection: Slip COUPLING NUT over 5/8'' O.D.supply tube and solder tube into UNION SWIVEL or female inlet of stop.

Install VALVE at indicated height and depth. Note MAX WALL marking on PLASTER GUARD for the finished wall.

Connect HOT water supply to left VALVE inlet and COLD water supply to right VALVE inlet. Tighten both COUPLING NUTS firmly.

Add cross braces to wall structure and secure piping.

Secure VALVE BODY to cross brass of wall structure.

Cap roughing-in nipples, open supply lines and check for leaks.

Remove PLASTER GUARD. (Do not discard.) Open valves, and check for leaks.

Close both valves, turn off water supplies, and replace

PLASTER GUARDS.

Finish wall construction. NOTE: Apply wall finish as close as possible to the PLASTER GUARD.

2 FINISHING INSTALLATION

Remove roughing-in nipples.

Remove SCREWS holding PLASTER GUARDS and remove

PLASTER GUARD.

Slip VALVE COVER over VALVE CARTRIDGE. Push VALVE COVER to complete stop.

Place O-RING in FIXATION PLATE as shown.

Place FIXATION PLATE over VALVE ASSEMBLY. Line up holes in FIXATION PLATE with THREADED TABS on VALVE.

Pass MOUNTING SCREWS (2) through FIXATION PLATE and engage THREADED TABS. Tighten SCREWS securely.

Place ESCUTCHEON over FIXATION PLATE and push evenly for a snap fit.

Assemble handle per separate "Handle Installation Instructions."

3 TEST INSTALLED FAUCET

 

 

CROSS

 

 

BRACE

"MAX WALL"

 

 

 

 

PIPE

 

 

STRAP

PLASTER

 

THREADED

A

TABS

GUARD

 

AL

 

M

X

 

 

W

 

 

L

VALVE

FIXATION

PLATE

 

VALVE

UNION

 

CARTRIDGE

 

SWIVEL

 

 

 

VALVE

 

 

COVER

 

O-RING

 

COUPLING

 

NUT

 

 

MOUNTING

 

 

SCREWS

 

 

 

 

SUPPLY

ESCUTCHEON

 

PIPE

Turn HANDLES into OFF position.

Turn on water supplies, open stops and check all connections for leaks.

4

SERVICE

SPRING

STOP

 

WASHER

 

 

CLIP

 

To change direction of handle rotation, proceed as follows:

Turn valve to OFF position.

Remove INSERT and HANDLE SCREW.

Slip HANDLE with ADAPTER off.

Remove SPRING CLIP.

Lift STOP WASHER, turn 90° and replace.

Replace SPRING CLIP.

Replace ADAPTER, HANDLE, SCREW, and INSERT.

If spout drips, operate handles several times from

OFF to ON position. Do not force - handles turn only 90°.

HOTLINE FOR HELP

For toll-free information and answers to your questions, call:

1 (800) 442-1902

Weekdays 8:00 a.m. to 7:00 p.m. Eastern Time Saturdays 8:00 a.m. to 4:00 p.m. Eastern Time

Operate HANDLE to flush water lines thoroughly.

Turn handles OFF.

To access CARTRIDGE:

Remove HANDLE and adapter.

Use thin blade screwdriver to remove ESCUTCHEON from FIXATION PLATE.

Unscrew MOUNTING SCREWS and pull FIXATION PLATE from wall. Pull off VALVE COVER.

Plastic SCREEN in CARTRIDGE may accumulate dirt causing reduced water flow. To clean, first turn off hot and cold water supplies, then:

Remove INSERT and HANDLE SCREW.

Slip HANDLE with ADAPTER off.

Unscrew CARTRIDGE with wrench.

Thoroughly rinse plastic SCREEN at base of CARTRIDGE.

Replace CARTRIDGE until flange is tight against valve body.

Turn valves OFF.

Replace ADAPTER, HANDLE, SCREW, and INSERT.

CARTRIDGE

SCREEN

IN CANADA 1-800-387-0369 (TORONTO 1-416-536-5609)

P r o d u c t n a m e s l i s t e d h e r e i n a r e t r a d e m a r k s o f A m e r i c a n S t a n d a r d I n c . C A m e r i c a n S t a n d a r d I n c . 1 9 9 9

3 4 8 0 3 N

Page 2
Image 2
American Standard 7006, 7000 ROUGHING-IN Fitting, Finishing Installation, Test Installed Faucet, Service

7000, 7006 specifications

The American Standard 7000 and 7006 are revered models in the world of heating and cooling, representing cutting-edge technology and exceptional performance. These systems are designed to provide efficient climate control while ensuring comfort and versatility for residential and commercial spaces alike.

One of the hallmark features of the American Standard 7000 series is its superior energy efficiency. These models utilize advanced inverter technology, allowing for variable-speed operation. This means that the units can adjust their cooling and heating output based on the specific needs of the environment. As a result, they consume less energy during operation, which can lead to significant cost savings on energy bills.

Both the 7000 and 7006 models incorporate a multi-stage filtration system, ensuring that airborne particles, allergens, and pollutants are effectively captured. This technology not only improves the overall air quality but also extends the lifespan of the system by preventing dust build-up on the internal components. The ease of access for cleaning and maintenance is another aspect that enhances the customer experience.

In addition to efficiency and air quality improvements, the American Standard 7000 series boasts advanced smart technology integration. Users can interact with their HVAC systems through smart home platforms, allowing for remote monitoring and control via mobile apps. This feature facilitates customized scheduling and energy usage tracking, empowering homeowners to optimize their air conditioning and heating preferences from anywhere.

The units are designed to operate quietly, a feature that is particularly appreciated in residential neighborhoods or office environments. The noise reduction technology used in these models minimizes operational sounds, creating a more peaceful indoor atmosphere.

The build quality of the American Standard 7000 and 7006 systems is robust, with a focus on durability and longevity. They are constructed with weather-resistant materials, suitable for a variety of climates, ensuring reliable performance year-round.

In summary, the American Standard 7000 and 7006 models are excellent choices for those seeking high efficiency, smart technology features, excellent air filtration, and quiet operation. Their combination of advanced technologies and durable design makes them a staple in modern heating and cooling solutions, offering comfort while leading to reduced energy consumption and enhanced indoor air quality.