American Standard 7270.001 installation instructions 7270.551, 7270.500, 7270.501, M 9

Models: 7270.501 7270.500 7270.001 7270.551

1 2
Download 2 pages 5.11 Kb
Page 1
Image 1
Installation Instructions

Installation Instructions

LABORATORY VALVES

Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.

7270.001
7270.500
(Water Valve)
(Air, Gas or Vacuum Valve)
7270.551
7270.501
(Air or Gas Valve with Integral Check)

(Air, Gas or Vacuum Valve)

 

M 9 6 8 4 8 3

ROUGHING-IN DIMENSIONS

 

 

 

 

 

7270.001

 

7270.551

INDEX AS REQUIRED

 

 

 

 

 

(AIR, GAS, VAC)

 

DEX CW

 

 

 

 

 

 

 

 

 

1" [25mm] HEX

3"

1" [25mm] HEX

3-1/4"

 

 

 

 

[83mm]

 

 

[76mm]

 

 

 

3/8" NPT MALE

3/8" NPT MALE

 

 

 

 

 

THREAD INLET

 

HREAD INLET

 

 

 

 

1/2"

 

 

 

1/2"

 

[13mm]

 

 

5-5/8"

[13mm]

 

5-5/8"

 

 

 

 

 

 

[143mm]

 

 

[143mm]

 

 

 

 

INDEXED "AIR", "GAS"

3-1/8"

INDEXED "AIR" OR "GAS"

3-1/8"

 

OR VACUUM

 

 

 

[79mm]

 

 

[79mm]

 

 

 

 

 

3/8" NPT MALE

1-7/8"

3/8" NPT MALE

 

1-7/8"

THREAD INLET

THREAD INLET

 

[48mm]

 

[48mm]

 

 

 

 

1/2"

 

 

1/2"

 

 

[13mm]

 

 

[13mm]

 

 

1/2"

7270.500

 

1/2"

 

INTEGRAL CHECK

 

 

IN SERRATED TIP

[13mm]

 

[13mm]

 

1-1/4"

 

 

1-1/4"

7270.501

[32mm]

 

 

[32mm]

 

 

 

4-1/2"

 

 

4-1/2"

 

 

[114mm]

 

 

[114mm]

 

TOOLS AND SUPPLIES REQUIRED

 

 

 

 

 

 

 

Teflon Tape

 

 

 

Adjustable Wrench

 

 

Plumbers' Putty or

 

 

 

 

Caulking

 